417102214_EDPL_V60.docx
99
Rev. 1.12.11
10.4.14.5 Oval gear meter pulse display (
V60
PLUS
only)
This display shows the number of pulses recorded during the last calibration process
(running time during calibration = 1 min).
If the value (
1
) shown is less than 60, metering monitoring using an
oval gear meter is only possible to a limited extent.
Fig. 10.45
10.4.15 Configuration / Batch
NOTE
The pump must be calibrated before using the batch metering.
(see chapter:
If batch mode is enabled, a pre-defined rate is metered with a stroke frequency of 100 % at
the metering lock or pulse input (plug II).
Batch metering can be interrupted by disabling the release (metering lock) or by switching off
the pump.
10.4.15.1 Selection
Fig. 10.46
-
Batch is inactive.
(Default setting)
Batch is active
If batch metering is active, the
following items appear in the submenu:
Menu option
see chapter
•
quantity
10.4.15.2 Batch / Quantity
Fig. 10.47
"Quantity" is used to
establish the desired
metering quantity
(in µl, ml, l or G) per batch
metering process.
Setting range:
0 – 99999
Содержание 417102214
Страница 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Страница 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Страница 120: ...417102214_EDPL_V60 docx 120 Rev 1 12 11 14 7 3 Pump capacity on type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Страница 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...