10.3.3.5 Metering quantity / pulse setting in the operating level
If the pulse interval setting is = 0 (see chapter
Setting the pulse interval
”)
the
metering quantity / pulse [ml / pulse] is configured / adjusted in the operating level. This can
also be done while the system is in operation.
Fig. 10.15
Pulse interval setting
≠ 0
(see chapter
„Setting the pulse interval“)
Pos. Description
1
Operating mode
2
metering quantity currently being processed [µl, ml, l]
(increases with every incoming pulse, decreases with
every processed metering stroke)
3
Configured metering quantity per pulse [ml / p.]
4
Active metering capacity in %
10.3.3.6 Metering quantity / pulse display during operation
Fig. 10.16
10.3.4 Operating mode / Current (External standard signal)
In the “current” operating mode, the pump functions on the basis of an incoming standard
signal. The incoming signal (0/4 - 20 mA; 20 - 0/4 mA or variable) is converted into a
metering frequency of 0-100 %.
The following operating options can be selected:
•
0 – 20 mA
0 mA = 0% metering frequency, 20 mA = 100 % metering frequency
•
4 – 20mA
4 mA = 0% metering frequency, 20 mA = 100 % metering frequency
•
20 – 0 mA
20 mA = 0% metering frequency, 0 mA = 100 % metering frequency
•
20 – 4 mA
20 mA = 0% metering frequency, 4 mA = 100 % metering frequency
•
variable
n (variable) mA = 0 % metering frequency,
n (variable) mA = 100 % metering frequency
Содержание 417102214
Страница 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Страница 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Страница 120: ...417102214_EDPL_V60 docx 120 Rev 1 12 11 14 7 3 Pump capacity on type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Страница 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Страница 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...