Parameter
Description
Setting range
Default
Vo
Velocity open (velocity open)
0…14 (5…50 °/s)
6
Vc
Velocity close (velocity close)
0…14 (5…0 °/s)
4
TOEx
Hold open time opening element inside / outside (time hold opening element inside/outside)
0…60 s
3 s
TKey
Hold open time Key (time hold opening element Key)
0…180 s
5 s
TDelay
Start-up delay (time delay lock)
0,0…4,0 s
0,2 s
FDelay
Relief force when unlocking (force delay), only works if TDelay is >0.
0,0…7,0 A
OFF
TLock
Door hold-up time (time press close)
0,0…4,0 s
0,5 s
FLock
Pressing force while locking (force lock), only works when TLock is >0.
0,0…7,0 A
2,0 A
FSlam
Slam function (force slam)
0…10
OFF
FWind
Obstacle detection optimised for external doors. (force wind)
OFF
OPEN
CLOSE
BOTH
OFF
Fo
Opening force (force open)
0…9
4
Fc
Closing force (force close)
0…9
4
Foh
Hold open force (force open hold)
0…9
0
Fch
Locking force (force close hold)
automatically sets FLock and FDelay if they are 0
0,0…3,5 A
0
Ao
Opening angle of the door (angle open)
If the opening angle is changed in the OPEN mode, the operating mode must be changed to
HAND to close the door.
20…(190 °) Rod dep. 95 °
*
Rod
Linkage types (Rod)
Standard arm pressing
Sliding rail pulling
Sliding rail pushing
Leaf mounting pushing
Without linkage pushing
Without linkage pulling
STD - PH
SLI - PL
SLI - PH
WIN - PH
DIR - PH
DIR - PL
STD - PH
*
Invers
Inverse-Application: In case of power failure / error, the door leaf is opened from any position
by spring force (if not locked). Position of the motor plug is reversed to the standard drive. The
electric lock / holding magnet must be connected in reverse to the standard drive (see wiring
diagram E4-0141-713).
OFF
ON
OFF
*
dAxis
Distance between door hinge rotation axis and the drives mounting level (distance Axis). dAxis
is a guide value. Depending on the mounting situation, dAxis must be adapted accordingly.
-8…+25 cm
Rod dep.
0 / +8 cm
Rod dep.
*
Fos
Limitation of the opening force.
Must not be increased in Germany!
5…14 A
5 A
*
Note: A new set-up process (Teach) is required.
SETTINGS
DRIVE PARAMETERS
(PARAMETER)
ECO
ETS – Assembly Buddy
26
Содержание ETS Series
Страница 1: ...ECO ETS ASSEMBLY BUDDY AUTOMATIC SWING DOOR DRIVE SYSTEM TECHNOLOGY FOR THE DOOR...
Страница 5: ......
Страница 12: ...CABLE PLAN ECO ETS 73 MASTER ECO ETS 64 R MASTER ECO ETS Assembly Buddy 12...
Страница 13: ...CABLE PLAN ECO ETS 64 R WITH 24V 48V SIGNAL 13...
Страница 15: ...CABLE PLAN ECO ETS 73 OPTIONAL PRINT 15...
Страница 17: ...CABLE PLAN ETS 73 n ETS 64 n ETS 42 BEA FLATSCAN LZR LASER SENSOR 17...
Страница 20: ...ECO ETS Assembly Buddy CABLE PLAN MOTOR LOCKS WITH DIRECT CONNECTION OF THE COIL 20...
Страница 21: ...CABLE PLAN MOTOR LOCKS WITH OWN EVALUATION CONTROL 21...
Страница 22: ...ECO ETS Assembly Buddy CABLE PLAN MOTOR LOCKS WITH SEPARATE EVALUTATION CONTROL AND POWER SUPPLY 22...
Страница 34: ...ECO ETS Assembly Buddy 34...
Страница 35: ...35...