Operating
No.
Description
Cause
Solution
Testing time
Reaction
E10
01
Fullteach
required
Parameter Ao, Rod, Invers
or dAxis changed
Proceed Teach
When changing
the drive configu-
ration
H
02
Minimum opening angle
not reached
Check locking / electronic lock
During the Teach
E11
01
Halfteach
required
(Opening)
Parameter Vo changed
Proceed complete, unobstructed
opening cycle
When changing
the ride parame-
ters
W
02
Halfteach
required
(Closing)
Parameter Vc or FSlam chan-
ged
Proceed complete, unobstructed
closing cycle
E14
01
Locking /
Electronic lock
Door leaf stucks in the locking /
electronic lock.
Check function of locking / electronic lock
When opening
from close-
position
H
02
Inverse-operation has no
locking or locking force Fch is
not adjusted
Adjust/increase locking force
At the end of the
Teach
W
E15
01
Obstacle in ope-
ning direction
Too many obstacles encounte-
red in a row
Check system
Remove obstacle
Move door leaf to target position
Permanently
H, A
Restart after
60 s
02
Obstacle in
closing direction
E16
01
Temperature
Temperature on output range
has reached 81° C
Observe the limits of use.
Permanently
A
Drive running
reduced
02
Temperature on output range
has reached 91° C
A
Drive stands
still
31
Содержание ETS Series
Страница 1: ...ECO ETS ASSEMBLY BUDDY AUTOMATIC SWING DOOR DRIVE SYSTEM TECHNOLOGY FOR THE DOOR...
Страница 5: ......
Страница 12: ...CABLE PLAN ECO ETS 73 MASTER ECO ETS 64 R MASTER ECO ETS Assembly Buddy 12...
Страница 13: ...CABLE PLAN ECO ETS 64 R WITH 24V 48V SIGNAL 13...
Страница 15: ...CABLE PLAN ECO ETS 73 OPTIONAL PRINT 15...
Страница 17: ...CABLE PLAN ETS 73 n ETS 64 n ETS 42 BEA FLATSCAN LZR LASER SENSOR 17...
Страница 20: ...ECO ETS Assembly Buddy CABLE PLAN MOTOR LOCKS WITH DIRECT CONNECTION OF THE COIL 20...
Страница 21: ...CABLE PLAN MOTOR LOCKS WITH OWN EVALUATION CONTROL 21...
Страница 22: ...ECO ETS Assembly Buddy CABLE PLAN MOTOR LOCKS WITH SEPARATE EVALUTATION CONTROL AND POWER SUPPLY 22...
Страница 34: ...ECO ETS Assembly Buddy 34...
Страница 35: ...35...