H. Connect the coax cable connectors 23K02P03 to the transponder lower antenna relay
coax receptacle marked NO (Normally Open)
I.
If transponder upper antenna relay installed, connect the coax cable connectors
23K03P03 to the transponder rupper antenna relay coax receptacle marked NO
(Normally Open)
J.
Connect the electrical connector 23K02P04 to the transponder lower antenna relay
electrical receptacle
.
K. If transponder upper antenna relay installed, connect the electrical connector 23K03P04
to the transponder upper antenna relay electrical receptacle
L.
Electrically bond the transponder lower antenna relay
to the structure. Refer to
AMM-20-03-00-051-801 – Electrical Bonding - Maintenance Practices.
Resistance must
be 2.5 milliohms or less.
4.
Job Close-Up
SUBTASK AMM-34-50-23-041-921-002
A. Remove all tools, equipment, and unwanted material from the work area.
B. If removed, install the air conditioning ducts. Refer to
AMM-21-20-11-041-801 – Cockpit
C. Install the 222 KZ - Multi Function Display (MFD). Refer to
Multi-Function Display - Installation.
D. Remove the warning placards.
E. Do the adjustment/test of the transponder system. Noting effectivity, refer to
AMM-34-50-20-071-801 – Transponder - Adjustment/Test
F. If all other maintenance is complete, return the aircraft to service. Refer to
AMM-20-00-02-051-801 – Return To Service (After Maintenance).
EA500 Aircraft Maintenance Manual — 06-117751
Temporary Revision No. 34-21
EFFECTIVITY: 0001-0104, 0113-0115, 0120, 0123-0124
POST SB 500-99-002; 0105-0112,
0116-0119, 0121-0122, 0125-0265 POST
SB 500-99-005; AND 0266-0267
34-50-23
Page 402-Inst
Sep 30/20
© 2020 Eclipse Aerospace, Inc.