(10) Bottom ERP should be between 48 to 60 dBm and MTL should be between -68 to
-80 dBm to PASS.
NOTE: If values are obtained and any of the individual tests FAIL during AUTO
TEST, press TEST LIST button on IFR 6000 and using UP/DOWN buttons
scroll to the specific Failed test(s). Press SELECT TEST button, adjust IFR
6000 test set positioning anywhere within a 30 foot arc between the aircraft’s
right wingtip and the nose as required, and Press RUN TEST button until
PASS Message is received (this may take several test set position
adjustments until IFR 6000 and aircraft Transponder “Sync up”). Press STOP
TEST button. Repeat until all individual FAILED tests have achieved a PASS.
It is not necessary to re-run AUTO TEST. AUTO TEST is a convenience
feature only.
NOTE: If POWER/FREQ test Fails: After pressing RUN TEST, adjust IFR-6000 test
set positioning while test is running until PASS message appears (this test
performs a “Live” update of the dBm values). It may be required to position
the test set anywhere within a 30 foot arc between the aircraft’s right wingtip
and the nose. Press the STOP TEST button as soon as PASS message is
displayed
(11) Remove Antenna Clamp and Shield Assembly.
(12) Set the WOW Box Switches to W-on-W (on-ground).