4.
Procedure – Upper Over Fin Fairing – NOT INSTALLED –
SUBTASK AMM-34-40-50-071-A-701-001
A.
Test Set-Up
NOTE: The operator should be familiar with the WX-PA Portable Analyzer Kit.
(1) Make sure that all aircraft power is off.
(2) Attach the WX-PA test set’s antenna to the Stormscope antenna.
(a) Position the WX-PA antenna on the Stormscope antenna as shown in
.
•
If necessary, use tape to secure WX-PA antenna; see
(b) Be sure to align the forwards arrows and position the WX-PA antenna suction
cups forward of center along the longitudinal axis.
(c) Attach antenna cable grounding clip to nearby structure to obtain a good ground.
See also
(3) Route the WX-PA antenna cable away from the aircraft.
(a) Connect the antenna cable to the WX-PA test box.
(b) DO NOT POWER UP THE TEST SET.
(4) On the IPL, set the SYS BATT and START BATT Switches to the ON (up) position
and BUS TIE to AUTO (up) position.
(a) Clear any “MASTER CAUTIONS” and “MASTER WARNINGS” as needed.
(b) On the MFD, press the PROCEED Line Select Key (LSK).
(5) If the aircraft is in the W-off-W condition, the following ECB’s must be collared:
CAUTION: IF THE PITOT/STATIC HEAT ECB’S ARE NOT COLLARED OFF,
HARM TO PERSONNEL OR AIR DATA TEST EQUIPMENT CAN
OCCUR.
(a) On the MFD ECB Page, scroll to ICE PROT and COLLAR the following ECBs:
•
ECB - DEICE MANIFOLD HTR (R AFT Bus)
•
ECB - L PITOT HEAT (L FWD Bus)
•
ECB - R PITOT HEAT (R FWD Bus)
•
ECB - L STATIC HEAT (BATT Bus)
•
ECB - L STATIC HEAT (R FWD Bus)
•
ECB - R STATIC HEAT (R FWD Bus)
•
ECB - R STATIC HEAT (L FWD Bus)
•
ECB - STBY PITOT HEAT (BATT Bus)
•
ECB - L WINDSHIELD HEAT (L AFT Bus)
•
ECB - R WINDSHIELD HEAT (R AFT Bus)
(6) On the MFD ECB AVIONICS synoptic page, ensure the following ECB is AUTO-ON:
EA500 Aircraft Maintenance Manual — 06-117751
Temporary Revision No. 34-21
EFFECTIVITY: 0001 - 0008, 0010 - 0050, 0052, 0054 -
0267 PRE SB 500-31-024
34-40-50
CONFIG A
Page 502
Sep 30/20
© 2020 Eclipse Aerospace, Inc.