System Design of UA 410 D
8
Firmware V1.40 - Doku 2.1 06. April 2016
2.2
Hardware
The case controller is housed in a plastic casing for DIN rail mounting and does not require any further optional
expansion modules. Up to 99 case controllers can be used within the E*LDS system. As required, a BT 300 x
Operator Interface and up to 4 BT 30 Temperature Displays can be connected. For a firmware update, the con
troller can be connected to a laptop or PC via the USB interface. The application range of the temperature
recording controller is described in more detail in chapter 3.2.
The following diagram illustrates the system architecture of the UA 410 D AC case controller (complete):
CAN bus
Digital outputs:
4 x normal open contact
3 x two-way-contacts
2 x 24 V DC / 50 mA
4 x
Analog inputs:
230 V
A
C
(1x)
BT 300
ESC
RESET
BT 30
(0..4x)
Case Controllers
(1..99)
Digital inputs:
2 x 4..20 mA
2-wire-NTC-
temperature sensors
2 x
Analog outputs:
0..10 V
USB
ZNR. 1
15 130 E1
MODE
ESC
PRIO 1
PRIO 2
,
0
ALARM
RESET
V4.24
AL 300
CI 3000
CI 3100
CI 4x00
Ports:
CAN bus:
Communication in E*LDS-System, new version
DISPLAY:
Connection for BT 300x Operator Interface
USB:
For conducting a firmware update
Inputs/outputs
4 digital inputs
230 V AC, floating
10 analog inputs
Connection for two-wire NTC temperature sensors
2 x analogue inputs
4..20 mA - currently without function
Outputs
3 relay output
230 V AC / 6 A (changeover)
4 relay outputs
230 V AC / 6 A (N.O.)
2 transistor outputs
24 V DC / 50 mA
2 x analogue outputs
0..10 V DC - currently without function
Real-time clock
Battery-backed, lithium cell
For precise details of the UA 410 D AC see chapter 3.1. The connection and terminal configurations
are described in the chapter Connection and Terminal Configuration.
Содержание UA 410 D
Страница 8: ...vi Firmware V1 40 Doku 2 1 06 April 2016 Notice ...
Страница 22: ...Application of UA 410 D 14 Firmware V1 40 Doku 2 1 06 April 2016 Notice ...
Страница 74: ...Pin and Terminal Assignments of UA 410 D 66 Firmware V1 40 Doku 2 1 06 April 2016 Notice ...
Страница 84: ...Operation of UA 410 D 76 Firmware V1 40 Doku 2 1 06 April 2016 Notice ...
Страница 132: ...Decommissioning and disposal 124 Firmware V1 40 Doku 2 1 06 April 2016 Notice ...
Страница 140: ...Specifications of UA 410 D 132 Firmware V1 40 Doku 2 1 06 April 2016 Notice ...
Страница 142: ...Order numbers and accessories of UA 410 D 134 Firmware V1 40 Doku 2 1 06 April 2016 Notice ...