A
IQ 250/260 Meter
Appendix B:
Modbus Mapping
80EF - 80F0
33008 - 33009
Output#4 Assignment and Kt
UINT16
2
80F1 - 80F1
33010 - 33010
Input Accumulators Scaling
UINT16
bit-mapped
44443333 22221111
1
80F2 - 80F2
33011 - 33011
Output Accumulators Scaling
UINT16
bit-mapped
44443333 22221111
1
80F3 - 8126
33012 - 33063
Reserved
Set to 0.
52
Block Size:
63
Second Overlay
write only in PS update mode
8127 - 812E
33064 - 33071
Input#1 Label
ASCII
16 char
8
812F - 8136
33072 - 33079
Input#1 Low State Name
ASCII
16 char
8
8137 - 813E
33080 - 33087
Input#1 High State Name
ASCII
16 char
8
813F - 8156
33088 - 33111
Input#2 Label and State Names
24
8157 - 8186
33112 - 33159
Reserved
Set to 0.
48
8187 - 818E
33160 - 33167
Relay#1 Label
ASCII
16 char
8
818F - 8196
33168 - 33175
Relay#1 Open State Name
ASCII
16 char
8
8197 - 819E
33176 - 33183
Relay#1 Closed State Name
ASCII
16 char
8
819F - 81B6
33184 - 33207
Relay#2 Label and State Names
24
81B7 - 81E6
33208 - 33255
Reserved
Set to 0.
48
81E7 - 81EE
33256 - 33263
Input#1 Accumulator Label
ASCII
16 char
8
81EF - 81F6
33264 - 33271
Input#2 Accumulator Label
ASCII
16 char
8
81F7 - 8206
33272 - 33287
Reserved
Set to 0.
16
8207 - 8207
33288 - 33288
Input#1 Accumulator Kt
UINT16
bit-mapped
ddVVVVVV VVVVVVVV
1
8208 - 8208
33289 - 33289
Input#2 Accumulator Kt
UINT16
bit-mapped
ddVVVVVV VVVVVVVV
1
8209 - 8326
33290 - 33575
Reserved
Set to 0.
286
Block Size:
512
Second Overlay
write only in PS update mode
8127 - 812E
33064 - 33071
Input#1 Label
ASCII
16 char
8
812F - 8136
33072 - 33079
Input#1 Low State Name
ASCII
16 char
8
8137 - 813E
33080 - 33087
Input#1 High State Name
ASCII
16 char
8
813F - 8156
33088 - 33111
Input#2 Label and State Names
24
8157 - 816E
33112 - 33135
Input#3 Label and State Names
24
816F - 8186
33136 - 33159
Input#4 Label and State Names
24
8187 - 818E
33160 - 33167
Output#1 Label
ASCII
16 char
8
818F - 8196
33168 - 33175
Output#1 Open State Name
ASCII
16 char
8
8197 - 819E
33176 - 33183
Output#1 Closed State Name
ASCII
16 char
8
819F - 81B6
33184 - 33207
Output#2 Label and State Names
24
81B7 - 81CE
33208 - 33231
Output#3 Label and State Names
24
81CF - 81E6
33232 - 33255
Output#4 Label and State Names
24
81E7 - 81EE
33256 - 33263
Input#1 Accumulator Label
ASCII
16 char
8
81EF - 81F6
33264 - 33271
Input#2 Accumulator Label
ASCII
16 char
8
81F7 - 81FE
33272 - 33279
Input#3 Accumulator Label
ASCII
16 char
8
81FF - 8206
33280 - 33287
Input#4 Accumulator Label
ASCII
16 char
8
Same as Input #1.
Same as Output #1.
Same as Output #1.
Same as Output #1.
Same as Output #1.
See Relay Card above.
Settings Registers for Digital I/O Relay Card
Same as Input #1.
Same as Relay #1.
Same as Input #1.
Same as Input #1.
KT power factor for the Pulse Output
"V" is raw power value in Wh/pulse from 0 to 9999.
"dd"=decimal point position: 00=0.XXXX, 01=X.XXX,
10=XX.XX, 11= X.XXX.
Settings Registers for Digital I/O Pulse Output Card
www.eaton.com
IB02601006E MM-23
Содержание IQ 250
Страница 2: ......
Страница 22: ...3 6 IB02601006E www eaton com Chapter 3 Mechanical Installation IQ 250 260 Meter...
Страница 38: ...4 16 IB2601006E www eaton com Chapter 4 Electrical Installation IQ 250 260 Meter...
Страница 100: ...A 2 IB02601006E www eaton com Appendix A IQ 250 260 Navigation Maps IQ 250 260 Meter Main Menu Screens Sheet 1...
Страница 101: ...Appendix A IQ 250 260 Meter IQ 250 260 Navigation Maps www eaton com IB02601006E A 3 Operating Mode Screens Sheet 2...
Страница 102: ...A 4 IB02601006E www eaton com Appendix A IQ 250 260 Navigation Maps IQ 250 260 Meter Reset Mode Screens Sheet 3...
Страница 103: ...Appendix A IQ 250 260 Meter IQ 250 260 Navigation Maps www eaton com IB02601006E A 5 Con guration Mode Screens Sheet 4...
Страница 104: ...A 6 IB02601006E www eaton com Appendix A IQ 250 260 Navigation Maps IQ 250 260 Meter...
Страница 134: ...A IQ 250 260 Meter Appendix B Modbus Mapping www eaton com IB02601006E MM 28...