Instruction Booklet 

IB0191004EN

Effective June 2020

EAFR-110PLV current and arc light 

sensor relay user manual 

  

EATON

 www.eaton.com

12. Ordering codes

12.1 EAFR relay codes

Eaton catalog number

Eaton style number

Part number description

EAFR-110P

65C2010G01

Current, point sensor unit

EAFR-110F

65C2010G02

Current, fiber loop sensor unit

EAFR-101

65C2010G03

Point sensor unit

EAFR-101D

65C2010G04

Point sensor unit, DIN rail mounted

EAFR-102

65C2010G06

Fiber loop sensor unit

EAFR-110PB

65C2010G07

Current, point sensor relay, NC trip relay

EAFR-110FB

65C2010G08

Current, fiber loop sensor relay, NC trip relay

EAFR-101B

65C2010G09

Point sensor relay, NC trip relay

EAFR-101DB

65C2010G10

Point sensor relay, DIN rail mounted, NC trip relay

EAFR-102B

65C2010G11

Fiber loop sensor relay, NC trip relay

EAFR-101C

65C2010G18

Point sensor unit with circuit breaker inputs

EAFR-110PLV

65C2010G17

Current, point sensor, AQD unit

EAFR-110PLV-B

65C2010G19

Current, point sensor, AQD unit, 24Vdc supply

2.2 EAFR-0x arc sensors

Eaton catalog number

Eaton style number

Part number description

EAFR-01-A

65C2011G01

Arc light point sensor - 8,000 Lux

EAFR-01-B

65C2011G02

Arc light point sensor - 25,000 Lux

EAFR-01-C

65C2011G03

Arc light point sensor - 50,000 Lux

EAFR-06-10

65C2013G01

Arc light plastic fiber sensor - 10 m (32.81 ft)

EAFR-06-15

65C2013G02

Arc light plastic fiber sensor - 15 m (49.21 ft)

EAFR-06-20

65C2013G03

Arc light plastic fiber sensor - 20 m (65.62 ft)

EAFR-06-25

65C2013G04

Arc light plastic fiber sensor - 25 m (82.02 ft)

EAFR-06-30

65C2013G05

Arc light plastic fiber sensor - 30 m (93.43ft)

EAFR-06-35

65C2013G06

Arc light plastic fiber sensor - 35 m (114.83 ft)

EAFR-06-40

65C2013G07

Arc light plastic fiber sensor - 40 m (131.23 ft)

EAFR-07-10

65C2014G01

Arc light glass fiber sensor - 10 m (32.81 ft)

EAFR-07-15

65C2014G02

Arc light glass fiber sensor - 15 m (49.21 ft)

EAFR-07-20

65C2014G03

Arc light glass fiber sensor - 20 m (65.62 ft)

EAFR-07-25

65C2014G04

Arc light glass fiber sensor - 25 m (82.02 ft)

EAFR-07-30

65C2014G05

Arc light glass fiber sensor - 30 m (93.43ft)

EAFR-07-35

65C2014G06

Arc light glass fiber sensor - 35 m (114.83 ft)

EAFR-07-40

65C2014G07

Arc light glass fiber sensor - 40 m (131.23 ft)

EAFR-07-45

65C2014G08

Arc light glass fiber sensor - 45 m (147.64 ft)

EAFR-07-50

65C2014G09

Arc light glass fiber sensor - 50 m (164.05 ft)

EAFR-08-10

65C2015G01

Arc light glass fiber sensor (high temperature) - 10 m (32.81 ft)

EAFR-08-15

65C2015G02

Arc light glass fiber sensor (high temperature) - 15 m (49.21 ft)

EAFR-08-20

65C2015G03

Arc light glass fiber sensor (high temperature) - 20 m (65.62 ft)

EAFR-08-25

65C2015G04

Arc light glass fiber sensor (high temperature) - 25 m (82.02 ft)

EAFR-08-30

65C2015G05

Arc light glass fiber sensor (high temperature) - 30 m (93.43ft)

EAFR-08-35

65C2015G06

Arc light glass fiber sensor (high temperature) - 35 m (114.83 ft)

EAFR-08-40

65C2015G07

Arc light glass fiber sensor (high temperature) - 40 m (131.23 ft)

EAFR-08-45

65C2015G08

Arc light glass fiber sensor (high temperature) - 45 m (147.64 ft)

EAFR-08-50

65C2015G09

Arc light glass fiber sensor (high temperature) - 50 m (164.05 ft)

Содержание EAFR-110PLV

Страница 1: ...eneral 2 3 Operation and configuration 5 4 Arc sensors 9 5 System self supervision 11 6 Connections 12 7 Wiring diagrams 13 8 Dimensions and installation 14 9 Testing 16 10 Troubleshooting guide 19 11...

Страница 2: ...uP Microprocessor 2 General The Eaton Arc Flash Relay EAFR 110PLV is a sophisticated micro processor based arc flash protection relay with combined current and arc sensing Combined current and arc se...

Страница 3: ...vice AQD for the maximum level of arc fault protection The main features of EAFR 110PLV 110 220 Vac 125 250 Vdc auxiliary power supply Three phase current inputs IL1 IL2 and IL3 1A 5A nominal One grou...

Страница 4: ...supervision Control and power supply Ig X3 12 11 10 9 8 7 6 5 4 3 2 1 1A 5A HSO1 1A 5A 1A 5A 1A 5A HSO2 T3 SW1 SW2 set x In Ig set x In Current 0 5 0 05 1 0 6 0 13 12 S1 S2 8 7 6 S3 5 4 3 S4 2 1 QD u...

Страница 5: ...ve condition If the arc sensor is activated the corresponding sensor channel LED will turn on if the activation is longer than 1 5 ms The sensor LED activation function is latched steady light To clea...

Страница 6: ...formed Also activated by pressure information Check why the sensor activated check the sensor continuity or perform system setup see Section 3 3 1 Auto configuration System setup S4 Amber Normal statu...

Страница 7: ...n previous memorized set up a dip switch anyone must be moved back and forth prior to performing auto configuration Timeout allowing new configuration is one minute Reconfiguration with more connectio...

Страница 8: ...trip criteria channel 3 in EAFR 110F Trip on light only Trip on light and over current Both signals are required simultaneously to trip 5 a b Selection of standard arc configuration type Standard arc...

Страница 9: ...as completely as possible One sensor per closed metal clad compartment should be utilized In open spaces such as the bus bar section arc sensors should be mounted maximum 2 m 6 5 ft apart The factory...

Страница 10: ...see Figure 8 Figure 8 EAFR 01 sensor connection step 2 3 Connect the other end of the cable to a sensor channel on the EAFR 101 or EAFR 110PLV relay see Figure 9 Figure 9 EAFR 01 sensor connection ste...

Страница 11: ...the ERROR LED is illuminated If a fiber sensor failure occurs the unit will go into Error mode The ERROR LED will turn on the SF relay will release and the corresponding faulty fiber sensor channel L...

Страница 12: ...gized again 6 2 Inputs 6 2 1 Current measurement inputs The EAFR 110PLV has four CT inputs for three phase current and earth current measurement Both phase current and earth current inputs may be conf...

Страница 13: ...iring diagrams Figure 17 EAFR 110PLV wiring diagram A A T2 CBFP T3 SF T1 T4 X2 1 2 13 12 11 10 9 8 7 6 X1 11 10 9 8 7 6 5 4 3 2 1 UAUX S1 S2 S3 S4 S5 Station battery _ EAFR 110PLV _ _ _ IL1 IL2 IL3 Ig...

Страница 14: ...t sensor relay user manual EATON www eaton com 8 Dimensions and installation The EAFR 110PLV is door mounted in standard 19 in 482 6 mm rack height of 4U and 1 4 of a relay wide Figure 18 EAFR 102 dim...

Страница 15: ...Figure 19 EAFR 110PLV dimensions in millimeters inches 3 D view POWER ERROR TRIP 1 TRIP 2 SEN 1 SEN 2 SEN 3 SEN 4 FIBER I IN L OUT M TRIP L1 L2 L3 Io BO1 BO2 ARC PROTECTION SET AQ 1 10 157 6 18 82 3 2...

Страница 16: ...corresponding sensor channel indication LED status is changed to ON 4 Verify the relay output s activation s by checking the circuit breaker status or by monitoring the trip contact status The circuit...

Страница 17: ...d configured to send light information 13 Press the SET push button to reset all indications and latches 14 If the binary input BI2 is utilized for master trip to activate the BI2 verify that a trip h...

Страница 18: ...s Sensor channel 1 setting Sensor channel 2 3 4 setting Circuit breaker failure protection CBFP in use yes no Object activated LED indication T1 and T2 active BO1 active Sensor channel 1 Sensor 1 Sens...

Страница 19: ...stance 10 m Power consumption of current inputs circuit 10 m 11 4 Trip relays T1 and T2 Number 3 NO 1 NC or 4 NO Rated voltage 250 Vac dc Continuous carry 5 A Make and carry for 0 5 s 30 A Make and ca...

Страница 20: ...degree back IP 20 Dimensions W x H x D mm W x H x D in 102 x 157 x 164 mm 4 02 x 6 18 x 6 46 in Package dimensions W x H x D mm in 230 x 120 x 210 mm 9 06 x 6 18 x 6 46 in Weight 0 7 kg 24 69 oz 1 0...

Страница 21: ...or 20 m 65 62 ft EAFR 06 25 65C2013G04 Arc light plastic fiber sensor 25 m 82 02 ft EAFR 06 30 65C2013G05 Arc light plastic fiber sensor 30 m 93 43ft EAFR 06 35 65C2013G06 Arc light plastic fiber sens...

Страница 22: ...ement between Eaton and the purchaser THERE ARE NO UNDERSTANDINGS AGREEMENTS WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOS...

Отзывы: