Page 29
Technical Documentation EASYRO
®
Water Treatment Systems© 2015 easymetal GmbH.
This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH.
The clean water outlet remains disconnected from the tank during the entire maintenance process
to avoid any residues in the drinking water tank.
Make sure the mixture adjustment screw (5) of the
system is closed (turn clockwise to the stop).
Should your system feature a setting here, remember
the number of turns or mark the position so that you
can reset the screw at the end of the maintenance
process.
PREPARING THE CLEANING SOLUTION
To prepare the cleaning solution, please open the canister from the basic maintenance kit.
Please use the included disposable gloves and breathing mask for your safety when opening
the concentrate.
Dilute the cleaning concentrate with fresh water according to the mixing table.
Then screw the cap back on the canister with the
cleaning solution and shake it until water and
concentrate are mixed thoroughly.
Insert the suction tube (included in basic
maintenance set) into the connector on the cap
of the canister.
Now disconnect the tube (6) from the outlet of
the pre-filter housing.
Take the straight connector (basic maintenance kit)
and connect this tube with the suction tube on
the canister by pushing the two tube ends into
the connector (7).
The EASYRO
®
480 has 2 connected fresh
water supply inlets.
Please remove these two tubes directly from the
system and use the Y-connector included in your
basic maintenance kit to connect both tubes.
Please make sure that all connections are fastened
firmly and do not leak.
5
Adjustment screw
Straight connector
6
7
Model
Amount of Concentrate
Amount of Water
EASYRO
®
60/120
250 ml cleaning concentrate
4.750 ml of water
EASYRO
®
240
500 ml cleaning concentrate
9.500 ml of water
EASYRO
®
480
2 x 500 ml cleaning concentrate
2 x 9.500 ml of water