Page 27
Technical Documentation EASYRO
®
Water Treatment Systems© 2015 easymetal GmbH.
This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH.
MAINTENANCE AND CARE
MAINTENANCE INSTRUCTIONS
The display of your EASYRO
®
shows “CHANGE FILTER”.
The maintenance interval of 4500 operating hours has therefore
expired.
The system must be serviced at this time.
Please read this maintenance instruction carefully and follow the steps outlined here.
Regularly servicing your EASYRO
®
system ensures a long working life of the membranes.
Please prepare all parts and components before starting the maintenance process. This includes
the required clean water for the cleaning solution. The amount is listed in the mixing table and
on the back of the canister of your basic maintenance kit.
YOU NEED FOLLOWING FOR THE MAINTENANCE:
•
1 wound thread filter, 1 MCR, 10´´ or 20´´ depending on your system type (included in your
maintenance kit)
•
Cleaning concentrate for flushing the membranes (included in the maintenance kit)
• 1 canister (included in your basic maintenance kit)
• 2 tubes Ø 10 mm (included in your basic maintenance kit)
• 1 straight connector tube (included in your basic maintenance kit)
• 1 plug (included in your basic maintenance kit)
• Clean water depending on system type (water amount according to table)
• 1 Y-connector (included in the EASYRO
®
480 basic equipment)
• 10 l bucket or similar container
• Disposable gloves (included in maintenance kit)
• Breathing mask (included in maintenance kit)
•
1 activated carbon filter 10“ or 20“ depending on requirement
•
1 softener cartridge 10“ or 20“ depending on requirement
**********************
CHANGE
FILTER
2016 - 09 - 16
**********************
Model
Amount of Concentrate
Amount of Water
EASYRO
®
60/120
250 ml cleaning concentrate
4.750 ml of water
EASYRO
®
240
500 ml cleaning concentrate
9.500 ml of water
EASYRO
®
480
2 x 500 ml cleaning concentrate
2 x 9.500 ml of water