background image

Page 38

Technical Documentation EASYRO

®

 Water Treatment Systems© 2015 easymetal GmbH. 

This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH.

Description

Art.No.

Note

MAINTENANCE SYSTEMS

Basic maintenance kit for EASYRO

®

 60/120

401130

Basic maintenance kit for EASYRO

®

 240

401131

Basic maintenance kit for EASYRO

®

 480

401132

Maintenance kit for EASYRO

®

 60/120

401133

Maintenance kit for EASYRO

®

 240

401134

Maintenance kit for EASYRO

®

 480

401135

ACCESSORIES

Oventrop mixing valve

400212

Wall panel

401153

Faucet for sink installation

400416

Grundfos central water system

400405

Submersible UV lamp

401075

Linear level regulator sensor

401261

Stainless steel tank 420 l with add-on kit

400889

Additional stainless steel tank 420 l

401145

Plastic tank 1000 l with add-on kit

401149

Additional plastic tank 1000 l 

401241

Plastic tank 2000 l with add-on kit

401169

Additional plastic tank 2000 l 

401262

Membrane vessel 8 l

401058

Membrane vessel 18 l

401060

Membrane vessel 50 l

401063

Membrane vessel 80 l

401064

Membrane vessel 200 l

400393

Membrane vessel 300 l

400394

CONTROL SYSTEM

Measuring transducer mounting rail

400309

Siemens LOGO logic module display 12/24 (0Ba8)

401322

Memory card for Siemens LOGO

400319

Содержание EASYRO 60

Страница 1: ...User Manual EASYRO 60 120 240 480 Version 2017 V8 01 ML...

Страница 2: ...The information contained in this manual supplied drawings and any parts lists are the intellectual property of easymetal GmbH and are subject to copyright law Neither this manual nor parts of it may...

Страница 3: ...OF THE SYSTEM Membranes 8 System Components and Connections 9 12 Control Elements and Functions 13 Technical Data 14 15 INSTALLATION AND COMMISSIONING Delivery Scope 16 Selecting an Installation Site...

Страница 4: ...chnical Documentation EASYRO Water Treatment Systems 2015 easymetal GmbH This information is subject to copyright laws and may not be reproduced or changed without express written permission of easyme...

Страница 5: ...acturer CERTIFICATION AND WARRANTY The system corresponds with the statutes 443 from December 21 1990 of the ministerial deci sion about technical precautions concerning systems to treat household dri...

Страница 6: ...and of the Council as of 15 December 2004 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEU Gazette of the European Com...

Страница 7: ...ury WARNING Describes a danger to life and health Non compliance may result in death or serious injury CAUTION Indicates a dangerous situation Non compliance may result in minor injury or property dam...

Страница 8: ...40 5 membranes EASYRO 480 10 membranes NOTE Treating highly turbid or polluted water can result in a filter blockage and or decreases the membrane flow rate WARNING Destruction of the membranes It is...

Страница 9: ...copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH Clean water outlet with mixing 10 mm JG 230 V AC 50 Hz Fresh water supply 3 4 outside thread Mi...

Страница 10: ...and may not be reproduced or changed without express written permission of easymetal GmbH SYSTEM COMPONENTS AND CONNECTIONS EASYRO 120 Coding of the EASYRO 120 Clean water outlet with mixing 10 mm JG...

Страница 11: ...and may not be reproduced or changed without express written permission of easymetal GmbH SYSTEM COMPONENTS AND CONNECTIONS EASYRO 240 Clean water outlet with mixing 10 mm JG Fresh water supply 3 4 o...

Страница 12: ...and may not be reproduced or changed without express written permission of easymetal GmbH SYSTEM COMPONENTS AND CONNECTIONS EASYRO 480 Clean water outlet with mixing 10 mm JG Fresh water supply 3 4 o...

Страница 13: ...ESC OK EASYRO We 11 12 Stand by bar 5 Pressure vessel 2016 09 16 Display shows STAND BY mode The system is not in production mode possibly the tank is full The fill level is displayed as a bar on the...

Страница 14: ...10 l min Line pressure flowing 2 6 bar 2 6 bar Equipment connection 3 4 outer thread 3 4 outer thread Wastewater connection JG 10 mm JG 10 mm Faucet tap incl incl Dishwasher connection incl HYDRAULIC...

Страница 15: ...ewater connection JG 10 DN 20 JG 10 DN 20 JG 10 DN 20 Output Adjustable 0 200 S cm HYDRAULIC OUTPUT Output 24 hrs 2400 l 4800 l 9600 l Adjustable output pressure 2 5 bar 2 5 bar 2 5 bar Steel tank Nir...

Страница 16: ...ERY SCOPE EASYRO 60 120 240 or 480 Pre filter system with matching filter key in 10 or 20 depending on EASYRO model Filter inserts for the pre filter system depending on water quality of the inlet wat...

Страница 17: ...PREPARING FOR INSTALLATION NOTE If you have an EASYRO whole house installation an Oventrop valve with emergency bypass function and a mixture adjustment screw must be installed by a qualified authoris...

Страница 18: ...pre filter housing Select the mounting space in such a way that the pre filter system remains easily accessible for future maintenance work and filter replacements Use the drilling template to determ...

Страница 19: ...ve to install the pre filters on the wall Use the drilling template to determine the distances of the required drill holes The holes must have a diameter of 10 mm Use the enclosed fastening elements d...

Страница 20: ...VE Austrian Electrotechnical Association The system must feature the corresponding protection devices residual current operated circuit breakers and line protection switches fuses IMPORTANT Please no...

Страница 21: ...duced or changed without express written permission of easymetal GmbH INSTALLING THE EASYRO 60 IN ACABINET Connection plan of an AQUASHERIFF water treatment system shown here with a membrane vessel fo...

Страница 22: ...tems 2015 easymetal GmbH This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH INSTALLATION OF A WHOLE HOUSE EASYRO 12...

Страница 23: ...tems 2015 easymetal GmbH This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH INSTALLATION OF A WHOLE HOUSE EASYRO 24...

Страница 24: ...tems 2015 easymetal GmbH This information is subject to copyright laws and may not be reproduced or changed without express written permission of easymetal GmbH INSTALLATION OF A WHOLE HOUSE EASYRO 48...

Страница 25: ...ent granulate or an activated carbon filter as a part of your delivery scope please insert this filter into the first chamber In the second chamber please insert the wound thread filter Screw down the...

Страница 26: ...ing table After the flushing process disconnect the system again from the mains power supply and connect the clean water outlet with your tank Now reconnect the system to the mains power supply The sy...

Страница 27: ...U NEED FOLLOWING FOR THE MAINTENANCE 1 wound thread filter 1 MCR 10 or 20 depending on your system type included in your maintenance kit Cleaning concentrate for flushing the membranes included in the...

Страница 28: ...urn the screw 3 of the filter housing with a screwdriver until the pressure can escape Main water supply valve Oventrop fitting Screw of filter housing Model Max Output Amount EASYRO 60 120 approx 5 l...

Страница 29: ...ng concentrate with fresh water according to the mixing table Then screw the cap back on the canister with the cleaning solution and shake it until water and concentrate are mixed thoroughly Insert th...

Страница 30: ...HANGE FILTER or no text depending on model Press ESC left arrow for 5 seconds Suction for cleaning the membranes CHANGE FILTER 2016 09 16 EASYRO MEMBRANE CLEANING PROCESS Now the system aspirates the...

Страница 31: ...aterial is almost completely dissolved Nevertheless please clean the filter housing and the inserts of both chambers with lukewarm water Replace the gasket rings and screw down the union nut with the...

Страница 32: ...es back into the corresponding connections of the system Reopen the main water supply 11 and make sure all tubes and connections are correctly positioned and do not leak Reinsert the power plug into t...

Страница 33: ...eration NO MAINTENANCE AVAILABLE If you do not have a maintenance kit available it is possible to delay the maintenance interval for further 50 hours of production NOTE This bridging should only be us...

Страница 34: ...and gates and have ac cess to the main water valve or tap unless this is next to the EASYRO unit CLEANING AND CARE IMPORTANT Never clean the EASYRO unit with a steam cleaner Use a soft damp cloth to...

Страница 35: ...he system The inlet pressure has dropped and the system stops the production mode Possible measures 1 Make sure the water supply is turned on 2 Check if maybe pre filters are clogged requires filter r...

Страница 36: ...here is enough water in the tank TANK EMPTY This message appears only with systems equipped with an pressurized tank The internal pressure is too high This message is not used during standard operatio...

Страница 37: ...housing 10 400370 Single filter housing 20 400361 Double filter housing 10 400332 Double filter housing 20 400362 Wound thread filter 1 MCR 10 400342 Wound thread filter 1 MCR 20 400349 Wound thread...

Страница 38: ...g valve 400212 Wall panel 401153 Faucet for sink installation 400416 Grundfos central water system 400405 Submersible UV lamp 401075 Linear level regulator sensor 401261 Stainless steel tank 420 l wit...

Страница 39: ...echnical Documentation EASYRO Water Treatment Systems 2015 easymetal GmbH This information is subject to copyright laws and may not be reproduced or changed without express written permission of easym...

Страница 40: ...easymetal GmbH Resselstrasse 12 A 2120 Wolkersdorf office easymetal com www easymetal com...

Отзывы: