~ 39 ~
As shown in the picture, use a cable stripper to strip off the network cable, pass the network
cable through the components as shown in the figure, fit and press the network cable into the
RJ45 connector according to the cable color order of 1 to 8. For the other end of the network
cable, strip off the insulation layer of line 5 (blue and white) and line 4 (blue) by10 mm. Connect
line 4 (blue and white) to the RS485B port of the meter, and line 5 (blue and white) to the
RS485A port of the meter. Connect the L and N cable of the power grid circuit breaker side to
the "INPUT"/" LN "port of the DDS3366D meter or to the port 1 (phase line input) and the port 3
(neutral line input) of the DDS3366D-1 meter. (After confirming all the operation above, it is
available to switch on the power grid circuit breaker to power up the electricity meter and
configure the meter refer to 6.5.2 Electricity Meter Configuration. After the meter is configured,
disconnect the circuit breaker on the power grid side, continue other further operation.) Double
check whether the L/N cable of the network cable is securely connected.
6.4.2 Electricity Meter Configuration
DDS3366D
DDS3366D-J
Press “set” on the electricity meter to enter
the setting interface.
Ensure the parameters are set correctly.
Enter the parameter setting interface, Press
“▲” and “▼” to adjust parameters and “set”
to save these parameters.
After setting all parameters, press “set” to
enter the setting interface.
Press "SET" button on the electric meter to
enter the setting interface to adjust the
parameter, press "▲" "▼" button on the
electricity meter to adjust and switch; Press
"SET" again to confirm.
Switch to "
" and press "SET" to return
to main interface.
Password Interface
Press “SET” to enter the password input
interface.
Press “▲” to adjust the value and “▼” to
change the digit. Set the PSD password to
3366.
Press “SET” to enter the “HA” setting
interface.
Press the "SET "button to enter the password
setting interface.
Press "A " to adjust the number size, and
press "V" to switch.
Number, set the PSD password to 3366.
Press SET to enter the parameter setting
interface.
Содержание EAHI-6000-SL-S
Страница 66: ...64...