ICA-D212-725 (96)
Page 88 of 90
CHAPTER 96 – ELECTRICAL SYSTEM (96-00-00)
COPYRIGHT
2007 BY DART AEROSPACE LTD.
THIS DOCUMENT IS PRIVATE AND CONFIDENTIAL AND IS SUPPLIED ON THE EXPRESS CONDITION THAT IT IS NOT TO BE USED FOR ANY PURPOSE OR COPIED OR COMMUNICATED TO ANY
OTHER PERSON WITHOUT WRITTEN PERMISSION FROM DART AEROSPACE LTD.
Revision:
4
Date: 11.06.01
96.13 MISCELLANEOUS
ELECTRICAL
SYSTEMS
Miscellaneous electrical systems include the
windshield wipers, engine fire extinguisher, and
the cargo release system.
96.13.1 Windshield
Wipers
With the WIPER SEL switch, wipers can be
operated individually or simultaneously. With
WIPERS speed control switch, wipers can be
energized at LOW, MED, and HIGH speeds,
de-energized in the OFF position, and PARK.
PARK position is spring loaded (returns to OFF)
for stowing wiper blades to a location where vision
is not obstructed.
96.13.2
Operational Check – Windshield
Wiper
CAUTION
WINDSHIELDS SHALL BE
PROTECTED AGAINST
SCRATCHING BY WIPER BLADES
NOTE
Wiper blades may be held up off
windshields by lifting blade and
inserting a suitable pin into the hole
at the base of the wiper arm.
96.13.3.1
Apply electrical power to helicopter
electrical system.
96.13.3.2
Set WIPER SEL switch to BOTH.
Verify pilot and copilot wipers operate in
accordance with WIPERS speed control in HIGH,
MED, LOW, OFF, and PARK positions (OFF the
wipers may stop in any position on the windshield,
PARK the wipers shall stop in the park position at
the end of the travel closest to the top of the
windshield).
96.13.2.3
Set WIPER SEL switch to PILOT.
Verify only pilot wiper operates in accordance with
WIPERS speed control in HIGH, MED, LOW,
OFF, and PARK positions.
96.13.2.4 Set WIPER SEL switch to
COPILOT. Verify only copilot wiper operates in
accordance with WIPERS speed control in HIGH,
MED, LOW, OFF, and PARK positions.
96.13.2.5 Open WINDSHIELD WIPER
COPLT circuit breaker. Repeat step 96.13.2.3.
96.13.2.6 Close WINDSHIELD WIPER
COPLT circuit breaker and open WINDSHIELD
WIPER PILOT circuit breaker. Repeat step
96.13.2.4.
96.13.2.7
Turn electrical power off.
96.13.3
Engine Fire Extinguisher System
NOTE
S/Ns 30817, 30931, 30687, 30576
and 30599 are fitted with an ENG
FIRE “T” handle. All S/Ns except
30817, 30931, 30687, 30576 and
30599 are fitted with ENG FIRE
and FIRE EXTING switch-lights.
The engine fire extinguisher system consists of a
fire extinguisher discharge switch, located on the
instrument panel above the fire handle or FIRE
EXTING switch-lights located on the instrument
panel at each crew station, and a fire extinguisher
cartridge located on the left side of the service
deck aft of the engine.
When a fire occurs in the engine compartment, the
fire detector amplifier (Z4) causes the FIRE 1
PULL handle or the ENG FIRE switch-light to
illuminate. In the event that fire extinguishing
action is required, pulling the FIRE 1 PULL handle
or lifting either safetied cover and pressing the
ENG FIRE switch-light will arm the squib on the
extinguisher bottle and illuminate the FIRE
EXTING switch-lights. Actuating the FIRE EXT
switch or pressing either illuminated FIRE EXTING
switch-light will discharge the extinguisher bottle.
96.13.4
Operational Check – Fire
Extinguisher Discharge Circuit
Содержание ICA-D212-725
Страница 2: ......
Страница 19: ......
Страница 47: ......
Страница 55: ......
Страница 71: ......
Страница 73: ......
Страница 75: ......
Страница 95: ......
Страница 121: ......
Страница 137: ......
Страница 149: ......
Страница 249: ......
Страница 251: ......
Страница 325: ......
Страница 327: ......
Страница 473: ......
Страница 475: ......
Страница 531: ......
Страница 581: ......
Страница 707: ......
Страница 729: ......