42
Coding the current rating within the CAN message
0x0
channel OFF
0x1
channel ON
8 Tests and technical data
8.1 Environmental testing and approvals
The following approval test was carried out for all SCS200 versions:
The following tests were carried out for all SCS200 versions:
Name
Chapter/section
Comments
E1
Directive R-10, regulatory status 5
KBA, approval mark E1*10R05/01*9019*00
Name
Chapter/section
Comments
ISO 16750-2
4.2
DC supply voltage
ISO 16750-2
4.3
Overvoltage
ISO 16750-2
4.4
Superimposed AC voltage
ISO 16750-2
4.5
Slow decrease or increase of supply voltage
ISO 16750-2
4.6.1
Momentary drop in supply voltage
ISO 16750-2
4.6.2
Reset behaviour at voltage drop
ISO 16750-2
4.6.3
Starting pulses
ISO 16750-2
4.6.4
Load dump
ISO 16750-2
4.7
Reversed voltage
ISO 16750-2
4.8
Ground reference and supply offset
ISO 16750-2
4.9.1
single line interruption
ISO 16750-2
4.9.2
multiple line interruption
ISO 16750-2
4.10.2
short circuit in signal circuits
ISO 16750-2
4.10.3
Short circuit load circuits
ISO 16750-3
4.1.2.7
Vibration -
ISO 16750-3
4.2.2
Mechanical shock
ISO 16750-3
4.3
Free fall
ISO 16750-4
5.1.1.1
Storage at -40 °C
ISO 16750-4
5.1.1.2
Operation at -40 °C
ISO 16750-4
5.1.2.1
Storage at +90 °C
Byte
Bit
Description
Value
Byte 7
not used
0x00
Byte 8
not used
0x00