36
PGN 65290 – Proprietary B
Transmission Rate:
as requested by the user or in the event of value change, max. 100 ms
Data Length:
8 bytes
Data page:
0
PDU format
255
PDU Specific:
10
Default Priority:
6
Parameter Group Number: 65290 (FF0Ah)
CAN-ID 0x18FF0Axx
xx Node address SCS200
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Contents
channel 1
channel 2
channel 3
channel 4
Unit
10 mV
10 mV
10 mV
10 mV
CAN data
Byte
Bit
Description
Value
Byte 1
voltage at load 1
LSB voltage load 1
Byte 2
MSB voltage load 1
Byte 3
voltage at load 2
LSB voltage load 2
Byte 4
MSB voltage load 2
Byte 5
voltage at load 3
LSB voltage load 3
Byte 6
MSB voltage load 3
Byte 7
voltage at load 4
LSB voltage load 4
Byte 8
MSB voltage load 4
Overview set-up CAN data
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Contents
channel 5
channel 6
channel 7
channel 8
Unit
10 mV
10 mV
10 mV
10 mV
PGN 65288 – Proprietary B
Transmission Rate:
as requested by the user or in the event of value change, max. 100 ms
Data Length:
8 bytes
Data page:
0
PDU format
255
PDU Specific:
8
Default Priority:
6
Parameter Group Number: 65288 (FF08h)
CAN-ID 0x18FF08xx
xx Node address SCS200
Overview set-up CAN data