26
PGN 65299 – Proprietary B
Transmission Rate:
as requested by the user, max. 100 ms
Data Length:
8 bytes
Data page:
0
PDU format
255
PDU Specific:
19
Default Priority:
6
Parameter Group Number: 65299 (FF13h)
CAN-ID: 0x18FF13xx
xx Node address SCS200
Overview set-up CAN data
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Contents
Contents
EEPROM
address
0x78
Contents
EEPROM
address
0x79
Contents
EEPROM
address
0x7A
Contents
EEPROM
address
0x7B
Contents
EEPROM
address
0x7C
Contents
EEPROM
address
0x7D
Contents
EEPROM
address
0x7E
Contents
EEPROM
address
0x7F
Unit
–
–
–
–
–
–
–
–
CAN data
Byte
Bit
Description
Value
Byte 1
bits 8 – 5
Contents
EEPROM
address 0x78
current ratings channel 1
bits 4 – 1
current ratings channel 2
Byte 2
bits 8 – 5
Contents
EEPROM
address 0x79
current ratings channel 3
bits 4 – 1
current ratings channel 4
Byte 3
bits 8 – 5
Contents
EEPROM
address 0x7A
current ratings channel 5
bits 4 – 1
current ratings channel 6
Byte
Bit
Description
Value
Byte 5
bit 8
Contents
EEPROM
address 0x74
status fast disconnection channel 11
bits 7 – 5
basic ON delay channel 11
bits 4 – 1
multiplier ON delay channel 11
Byte 6
bit 8
Contents
EEPROM
address 0x75
not used
bits 7 – 5
basic ON OFF delay channel 11
bits 4 – 1
multiplier OFF delay channel 11
Byte 7
bit 8
Contents
EEPROM
address 0x76
status fast disconnection channel 12
bits 7 – 5
basic ON delay channel 12
bits 4 – 1
multiplier ON delay channel 12
Byte 8
bit 8
Contents
EEPROM
address 0x77
not used
bits 7 – 5
basic ON OFF delay channel 12
bits 4 – 1
multiplier OFF delay channel 12
Содержание SCS200