24
PGN 65297 – Proprietary B
Transmission Rate:
as requested by the user, max. 100 ms
Data Length:
8 bytes
data page
0
PDU Format:
255
PDU Specific:
17
Default Priority:
6
Parameter Group Number: 65297 (FF11h)
CAN-ID: 0x18FF11xx
xx node address SCS200
Overview set-up CAN data
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Contents
Contents
EEPROM
address
0x68
Contents
EEPROM
address
0x69
Contents
EEPROM
address
0x6A
Contents
EEPROM
address
0x6B
Contents
EEPROM
address
0x6C
Contents
EEPROM
address
0x6D
Contents
EEPROM
address
0x6E
Contents
EEPROM
address
0x6F
Unit
–
–
–
–
–
–
–
–
CAN data
Byte
Bit
Description
Value
Byte 1
bit 8
Contents
EEPROM
address 0x68
status fast disconnection channel 5
bits 7 – 5
basic ON delay channel 5
bits 4 – 1
multiplier ON delay channel 5
Byte 2
bit 8
Contents
EEPROM
address 0x69
not used
bits 7 – 5
basic ON OFF delay channel 5
bits 4 – 1
multiplier OFF delay channel 5
Byte 3
bit 8
Contents
EEPROM
address 0x6A
status fast disconnection channel 6
bits 7 – 5
basic ON delay channel 6
bits 4 – 1
multiplier ON delay channel 6
Byte 4
bit 8
Contents
EEPROM
address 0x6B
not used
bits 7 – 5
basic ON OFF delay channel 6
bits 4 – 1
multiplier OFF delay channel 6
Byte 5
bit 8
Contents
EEPROM
address 0x6C
status fast disconnection channel 7
bits 7 – 5
basic ON delay channel 7
bits 4 – 1
multiplier ON delay channel 7
Byte 6
bit 8
Contents
EEPROM
address 0x6D
not used
bits 7 – 5
basic ON OFF delay channel 7
bits 4 – 1
multiplier OFF delay channel 7
Содержание SCS200
Страница 1: ...User Manual SCS Smart Control Systems SCS200 intelligent power distribution...