42
9.
O
PERATION
9.1
P
RIMARY
I
NPUT
C
ALIBRATION
NOTE:
In this section the word
Calibration means to match the Instrument to the input device, so
that a specific signal from the input device is equated to a specific pressure and no other, (to
the capabilities of its input resolution).
Apply power to the cabinet and allow the system to stabilize for about 30 minutes. Allow the
transducer or other input device to come up to operating conditions.
9.1.1 C
ALIBRATION
OF
P
RESSURE
T
RANSDUCERS
E
QUIPPED
WITH
AN
I
NTERNAL
S
HUNT
R
ESISTOR
Be sure that the full scale and low scale values (
PI.FSV
and
PI.LSV
) have been set to match the range
of the transducer and that the
SHUNT
function is
ON
and set to the correct percentage (80% for a
typical Dynisco transducer).
To calibrate the transducer to the instrument, press the
FUNC
key until
nonE
and
GROUP
show on
the display. Press the
▲
key until
2
shows in the upper display. Press the
FUNC
key and the lower
display changes to
ZERO.C
. The upper display shows
OFF
. Press the
▼
or
▲
keys until the upper
display changes to
ON
. Press the
FUNC
key to calibrate the zero value. The lower display changes
to
SPAN.C
. The upper display shows
OFF
. Press the
▼
or
▲
keys until the upper display changes to
ON
.
Press the
FUNC
key to calibrate the span value. When the legend
DSP.FL
appears in the lower
display, calibration is complete. Press
RESET
to return to the operating screen.
9.1.2 C
ALIBRATION
OF
A
MPLIFIED
P
RESSURE
T
RANSMITTERS
E
QUIPPED
WITH
AN
I
NTERNAL
S
HUNT
R
ESISTOR
Be sure that the full scale and low scale values (
PI.FSV
and
PI.LSV
) have been set to match the range
of the transducer and that the
SHUNT
function is turned
OFF
.
To calibrate the transducer to the instrument, press the
FUNC
key until
nonE
and
GROUP
show on
the display. Press the
▲
key until
2
shows in the upper display. Press the
FUNC
key and the lower
display changes to
ZERO.C
. The upper display shows
OFF
. Press the
▼
or
▲
keys until the upper
display changes to
ON
. Press the
FUNC
key to calibrate the zero value. The lower display changes
to
SPAN.C
. The upper display shows
OFF
. Press the
▼
or
▲
keys until the upper display changes to
CLEAr. Press the
FUNC
key to calibrate the span value. When the legend
DSP.FL
appears in the
lower display, calibration is complete. Press
RESET
to return to the operating screen.
Содержание UPR700
Страница 14: ...14 Fig 2 Model UPR700 Outline Drawing...
Страница 16: ...16 Fig 3 UPR700 Wiring 4 20mATransmitter Internal 24VDC Power Supply Primary Input...
Страница 33: ...UPR700 Microprocessor Based Pressure Process Indicator 33 Fig 10 Secondary Input Jumper Location...
Страница 67: ...NOTES...
Страница 68: ...NOTES...
Страница 70: ...DYNISCO LLC 38 FORGE PARKWAY FRANKLIN MA 02038 ATTN MARKETING DEPT Place Stamp Here...
Страница 71: ......