24
7.4
O
PERATING
M
ODE
D
ESCRIPTION
The
FUNC
key is used to access the parameters organized in five groups. Use the
FUNC
pushbutton to access the Group 1 parameters; the last entry (showing
Group
and
None
is intended
to access the other groups of parameters, or pressing
FUNC
again returns to the normal display
mode. Each group has its own family of parameters, loosely grouped around the decreasing need to
change the parameters. Each group also has the ability to load its own default parameters and the
default values of the lower number groups.
8.
C
ONFIGURATION
8.1
H
ARDWARE
The UPR700 is shipped with the hardware jumpers set for the following:
1. Main Input (Pressure) - Strain Gage
2. Secondary Input (Temperature) - Thermocouple*
3. Main Output - Voltage
4. Secondary Output - Voltage*
*If equipped with this option.
In addition, the DIP switches controlling the software security lock codes are in the “OFF” positions.
Please ensure that the correct jumper settings for the input(s) and output(s) used in your particular
application are selected. It is necessary only to select the category (e.g. Voltage or Current). The
specific range will be chosen in the software menu.
8.2
P
ARAMETERS
The UPR700 parameters are grouped in five sections guarded by three security levels. The more
common parameters are in the first groups, with the higher Group numbers for those parameters an
operator would not normally modify. Each group can be reset to its default value by two keystrokes.
This also resets the parameters of any lower numbered group to default. If GROUP 5 is set to default,
the entire instrument is reset to its default parameters. If a unit does not have a particular option, its
parameters will not appear. For example, an instrument that does not have RS-485 communications
will skip those parameters related to communications. Likewise, if a particular function is turned off,
its other parameters will not appear. For example, if Alarm 2 is turned to
OFF
in Group 3, the
hysteresis, reset, filter, type, and threshold functions will not appear on screen. Nor will the alarm
appear on he bar graph display.
Содержание UPR700
Страница 14: ...14 Fig 2 Model UPR700 Outline Drawing...
Страница 16: ...16 Fig 3 UPR700 Wiring 4 20mATransmitter Internal 24VDC Power Supply Primary Input...
Страница 33: ...UPR700 Microprocessor Based Pressure Process Indicator 33 Fig 10 Secondary Input Jumper Location...
Страница 67: ...NOTES...
Страница 68: ...NOTES...
Страница 70: ...DYNISCO LLC 38 FORGE PARKWAY FRANKLIN MA 02038 ATTN MARKETING DEPT Place Stamp Here...
Страница 71: ......