Maintenance
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
91
Water condensation will accumulate in the water separator (2) of
the compressed air maintenance unit.
Proper setting
Water condensation must not rise up to the level of the filter
element (1).
Check the water level in the water separator (2) on a daily basis.
Fig. 52: Draining the water condensation
Drain water condensation as follows:
1.
Disconnect the machine from the compressed air supply.
2.
Place the collection tray under the drain screw (3).
3.
Disconnect the connection hose from the compressed air
supply.
4.
Unscrew the drain screw (3) completely.
5.
Allow water to drain into the collection tray.
6.
Re-tighten the drain screw (3).
7.
Connect the machine to the compressed air supply.
(1) - Filter element
(2) - Water separator
(3) - Drain screw
①
②
③
Содержание 610-10
Страница 1: ...610 10 630 10 Operating Instructions...
Страница 6: ...Table of Contents 4 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 16: ...Safety 14 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 44: ...Operation Operating Instructions 610 10 630 10 01 0 01 2021 42...
Страница 84: ...Settings via software Operating Instructions 610 10 630 10 01 0 01 2021 82...
Страница 96: ...Maintenance Operating Instructions 610 10 630 10 01 0 01 2021 94...
Страница 112: ...Decommissioning 110 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 116: ...Disposal 114 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 136: ...Troubleshooting Operating Instructions 610 10 630 10 01 0 01 2021 134...
Страница 140: ...Appendix Operating Instructions 610 10 630 10 01 0 01 2021 138 Fig 65 Dimensions for manufacturing a table top 2...
Страница 147: ......