Troubleshooting
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
131
6361
Warning
Machine ID not connected
• Check the connection of the
machine ID cable
• Replace the machine ID
• Replace the controller
6400
–
6999
Error
Internal error
• Switch the machine off and on
again
• Performing a software update
• Contact Customer Service
7551
–
7659
Error
• Internal error
• Cable disturbance
• Cables to the control panel
Interface defective
• Switch the machine off and on
again
• Eliminate source of disturbance
• Performing a software update
• Replace the cable
• Contact customer service
9310
Error
• CAN connector not plugged in
or faulty
• Tape unwinder faulty
• Replace the CAN connector
• Replace the tape unwinder
• Replace the controller
9320
Error
• Tape unwinder dirty
• Tape unwinder faulty
• Clean the tape unwinder
• Open the throttle
• Replace the tape unwinder
9910
Error
Tilt sensor:
• Machine head is tilted over
• Tilt sensor not assembled or
defective
• Erecting the machine head
• Fit or replace tilt sensor
Code
Type
Possible causes
Remedial action
Содержание 610-10
Страница 1: ...610 10 630 10 Operating Instructions...
Страница 6: ...Table of Contents 4 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 16: ...Safety 14 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 44: ...Operation Operating Instructions 610 10 630 10 01 0 01 2021 42...
Страница 84: ...Settings via software Operating Instructions 610 10 630 10 01 0 01 2021 82...
Страница 96: ...Maintenance Operating Instructions 610 10 630 10 01 0 01 2021 94...
Страница 112: ...Decommissioning 110 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 116: ...Disposal 114 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 136: ...Troubleshooting Operating Instructions 610 10 630 10 01 0 01 2021 134...
Страница 140: ...Appendix Operating Instructions 610 10 630 10 01 0 01 2021 138 Fig 65 Dimensions for manufacturing a table top 2...
Страница 147: ......