9.3 Hall Sensors/ Encoders & analog and
digital inputs and outputs
Terminal Desi-
gnation Description
Signal
direction
X1.1
+U
E
Supply voltage
electronic
-
X1.2
GND
Earth for electronic
-
X1.3
AIN0
analog input 0
Input
X1.4
DIN0
digital input 0
Input
X1.5
DIN1
digital input 1
Input
X1.6
DIN2 /
DOUT0
digital input 2 /
digital output 0
Input
Output
X1.7
CAN_HI CAN high
Bus
X1.8
CAN_LO CAN low
Bus
X1.9
/H1
Negated Hall-
sensor signal 1
Input
X1.10
/H2
Negated Hall-
sensor signal 2
Input
X1.11
/H3 / Inx
INegated Hallsen-
sor signal 3 /
Inc. Encoder Index
Input
X1.12
/A
Incr. encoder -
negated track A
Input
X1.13
/INX
Incr. encoder -
negated track B
Input
X1.14
+U
5V
Power supply Hall/
Enc +5V
Output
X1.15
GND
Earth fir Hall/enco
-
der
-
9.3 Hallsensor/ Encoder
& Analoge und
Digitale Ein- und Ausgänge
Klemme Bezeich-
nung
Beschreibung
Signal-
richtung
X1.1
+U
E
Spannungsversor-
gung Elektronik
-
X1.2
GND
Masse Elektronik
-
X1.3
AIN0
analoger Eingang 0 Eingang
X1.4
DIN0
digitaler Eingang 0 Eingang
X1.5
DIN1
digitaler Eingang 1 Eingang
X1.6
DIN2 /
DOUT0
digitaler Eingang 2/
digitaler Ausgang 0
Eingang
Ausgang
X1.7
CAN_HI
CAN high
Bus
X1.8
CAN_LO CAN low
Bus
X1.9
/H1
Negiertes
Hallsensorsignal 1 Eingang
X1.10
/H2
Negiertes
Hallsensorsignal 2 Eingang
X1.11
/H3 / Inx
Negiertes Hallse-
norsignal 2 /
Inc. Encoder
- Index
Eingang
X1.12
/A
Inc. Encoder -
Negierte Spur A
Eingang
X1.13
/B
Inc. Encoder -
Negierter Spur B
Eingang
X1.14
+U
5V
Spannungsversor-
gung für Hall/Enc
+5V
Ausgang
X1.15
GND
Masse für
Hall/Encoder
-
9 Terminal assignment
9 Anschlussbelegung
Содержание BGE 3508/6005