Maintenance
8-4
“Y” Strainer Screen Cleaning Procedure
•
Clean the screen
figure 48
(3-1) located inside the “Y”- strainer prior to every
installation.
•
Remove the end plug from the end of the strainer
outlet valve.
•
Position a container at the outlet valve. A couple of
5-gallon containers should do.
•
With the pump “off”, drain off the “HTF” until there
is no more flow.
•
Remove the top of the “Y”-strainer and extract the
screen
figure 48
(3-1).
•
The screen should be cleaned using warm water and
a soft bristled brush.
•
Reassemble and ensure that all fittings are tight.
•
The extracted “HTF” can be reused.
•
Air must be purged from the system. Refer to “Operation, Purging air from the
“HTF” circulation system” for instructions.
HR2250
*DANGER! It is very important that you read and understand this section before
operating the hose reel. Failure to follow the procedures and cautions in this manual
could let to injury and possible death!*
Precautions
Electric shock will result in death or serious injury.
•
The user is responsible for conforming to all applicable code requirements with
respect to grounding all equipment.
•
DO NOT touch unshielded components or terminal strip screw connections with
voltage present.
•
Install and close all covers before applying power or starting and stopping the hose
reel.
•
Before servicing:
-Disconnect all power.
-Place a “DO NOT TURN ON” label on the drive controller disconnect.
-Lock disconnect in the open position.
•
Disconnect all power including external control power that may be present servicing
the drive
Figure 48-Y-Strainer Screen
Содержание 600 GTS Series
Страница 2: ......
Страница 47: ...Appendix 9 3 Electrical Schematics Figure 56 600 GTS sub 40 Electrical Schematic...
Страница 48: ...Appendix 9 4 Figure 57 600 GTS Electrical Schematic...
Страница 49: ...Appendix 9 5 Figure 58 HR2250 Electrical Schematic...
Страница 50: ...Appendix 9 6 Figure 59 Trailer Wiring Schematic...