Introduction
How the System Works
The system uses a low-pressure,
open-fluid loop distribution system
with an atmospherically vented
fluid reservoir. A central heating
module warms the heat transfer
fluid. This heated fluid is pumped
through a distribution system loop,
passing through heat exchangers in
remote locations.
Two types of exchangers are
available: Portable Heat
Exchangers and Circulation Line
Heat Exchangers.
•
Portable Heat
Exchangers include a
heat transfer coil, fan
and thermostatic
temperature control. The heat
transfer fluid flows through the transfer coil, where heat is transferred to the air being
drawn through the coil by the fan. The coil is specially designed for optimum heat
transfer, without adding any moisture or combustion by-products to the air.
•
Circulation line heat exchangers use flexible hose with hydraulic-style quick couplers
for ease in hookup. Heat transfer occurs by direct contact heat transfer and radiant
heat conduction.
The mixing/booster unit can be utilized to:
•
Provide lower temperature fluid for concrete cure and radiant floor heat applications.
•
Provide dual temperature control with a single fluid circulation system.
•
Boost fluid flow and increase pumping distances.
Figure 7-How the System Works