Operation / Settings
Available ventilation modes
•
VC-CMV / VC-AC
V
olume
C
ontrolled -
C
ontrolled
M
andatory
V
entilation with PEEP.
V
olume
C
ontrolled -
A
ssist
C
ontrol with PEEP.
•
VC-SIMV (Optionally wit h Pressure Support)
V
olume
C
ontrolled -
S
ynchronized
I
ntermittent
M
andatory
V
entilation with PEEP.
•
SpnCpap C
ontinuous
P
ositive
A
irway
P
ressure
(Optionally wit h Pressure Support)
Spontaneous breathing with positive airway pressure.
For heart-lung resuscitation
During heart-lung resuscitation, the airway pressure Paw is limited to the set Pmax value by the
Oxylog 2000
plus
,
without ending inspiration prematurely (pressure-limited, nonconstant-volume ventilation when Pmax is reached).
If Pmax is set to a higher value, a higher minute volume is possible.