Copyright © Dr Robot Inc. 2005
6
2. From the Run dialogue box, type the following command (where x.x.x.x is the IP
address and 9999 is the unit’s fixed network configuration port number):
Windows: telnet x.x.x.x 9999
UNIX: telnet x.x.x.x:9999
3.
Click OK. The following information displays:
Figure V.1. MAC Address
MAC address 00204AFFFF30
Software version 05.3(040129)WPT
Press Enter to go into Setup Mode
4. To enter the Setup Mode, press Enter within 5 seconds.
Note:
Connection fails if Enter is not pressed within 5 seconds.
The configuration settings display, followed by the setup menu options:
Figure V.2. Setup Menu Options
Change Setup:
0 Server
1 Channel 1
2 Channel 2
3 Email
4 WLAN
5 Expert
6 Security
7 Factory defaults
8 Exit without save
9 Save and exit Your choice ?
5. Select an option on the menu by entering the number of the option in the Your choice ? field
and pressing Enter.
View the current configuration by pressing Enter from the Change Setup menu. To enter a
value for a parameter, type the value and press Enter. To confirm a current value, press
Enter (without inputted parameters).
6. When finished, save the new configurations (9 Save and exit). The unit reboots.
V.1.2.
Serial Port Access
To configure the unit through a serial connection:
1. Connect a console terminal or PC running a terminal emulation program to your unit's
serial port. The default serial port settings are 9600 baud, 8 bits, no parity, 1 stop bit, no flow