Configuration via Serial Mode or Telnet Port
Configure the unit so that it can communicate on a network with your serial device.
The WFS802g unit is configurable using a terminal program to access the serial port locally. Using this terminal
program to respond to prompts is referred to as the Setup Mode. A Telnet connection may also be used to configure
the unit over the network.
The unit’s configuration is stored in nonvolatile memory and is retained without power. You can change the
configuration at any time. The unit performs a reset after the configuration has been changed and stored.
Note: The menus in this section show a typical device. Not all devices display information in the same manner.
This chapter includes the following topics:
.
Accessing Setup Mode
.
Server Configuration
.
Channel 1 and Channel 2 Configuration
.
Email Configuration
.
WLAN Settings
.
Expert Settings
.
Security Settings
.
Factory Defaults
.
Exit Configuration Mode
Figure V.1 Connection WFS802g with MCR3210P RS232 Interface Module
V.1.
Accessing Setup Mode
V.1.1.
Telnet Access
To configure the unit over the network, establish a Telnet connection to port 9999:
1. From the Windows Start menu, click Run.