33
this field.
Modem Mode
Indicates the on-screen response type when in Modem Mode
(if enabled).
Endpoint Configuration
Local Port
Enter the local port number.
Auto increment
local port number
Select to auto-increment the local port number for new outgoing
connections. The range of auto-incremented port numbers is 50,000 to
59,999 and loops back to the beginning when the maximum range is
reached.
Remote Port
Enter the remote port number.
Remote Host
the IP address of the remote device.
Common Options
Telnet Mode
This field is available for configuration only when Active Connection is not set
to None. Select Enable to permit Telnet communication to the WFS802g
unit
Terminal Name
This field is available for configuration only when Telnet Mode is set to
Enable.
Use the terminal name for the Telnet terminal type. Enter only one name.
When this option is enabled, the unit also reacts to the EOR (end of record)
and binary options, which can be used for applications such as terminal
emulation to IBM hosts.
Connect Response
A single character is transmitted to the serial port when there is a change in
connection state. Default setting is None.
Use Hostlist
If this option is set to True, the device server scrolls through the host list
until it connects to a device listed in the host list table. Once it connects, the
unit stops trying to connect to any others. If this connection fails, the unit
continues to scroll through the table until it is able to connect to another IP
in the host list.
The host list is disabled for Manual Mode and for Modem Mode. The unit will
not accept a data connection from a remote device when the host list option
is enabled.
LED
Select Blink for the status LEDs to blink upon connection or
None for no LED output.
Disconnect Mode
On Mdm_Ctrl_In
Drop
Set to Yes for the network connection to or from the serial port to drop when
modem_control_in transitions from a high state to a low state.
Hard Disconnect
When set to Yes, the TCP connection closes even if the remote site does not
acknowledge the disconnect request.
With EOT
Choose Yes to drop the connection when Ctrl-D or Hex 04 is detected. Both
Telnet mode and Disconnect with EOT must be enabled for Disconnect with
EOT to function properly. Ctrl D is only detected going from the serial port to
the network.
Inactivity Timeout
Use this parameter to set an inactivity timeout. The unit drops the connection
if there is no activity on the serial line before the set time expires. Enter time in
the format mm:ss, where m is the number of minutes and s is the number of
seconds. To disable the inactivity timeout, enter 00:00.
VI.5.3.
Connection Settings - UDP
To configure a channel’s UDP settings
:
1. From the main menu, click Connection for either Channel 1 or Channel 2 to display the
Connection Settings page for the selected channel.