Disable Web Server
The Y (Yes) option disables the web server. This setting defaults to the N (option).
Disable Web Server (N) ?
Disable Web Setup
The Y (Yes) option disables configuration via the Web-Manager. This setting defaults to the N (option).
Disable Web Setup (N) ?
Disable ECHO Ports
This setting controls whether the serial port echoes characters it receives. The current value is displayed
in parent.
Disable ECHO ports (Y) ?
Enable Enhanced Password
This setting defaults to the N (option), which permits a 4-character password protecting Setup Mode by
means of Telnet and web pages.
Enable Enhanced Password (Y) ?
The Y (Yes) option allows an extended security password of 16-characters for protecting
Telnet access.
Disable Port 77F0 (Hex)
Port 77F0 is a setting that allows a custom application to query or set the eleven WFS802g
configurable pins when they are functioning as general purpose I/O (GPIO). Disable this
capability, if desired, for security purposes.
Disable Port 77F0h ?
The default setting, the N (No) option, enables GPIO control. The Y (Yes) option disables the
GPIO control interface.
V.8.
Factory Defaults
Select 7 Factory Defaults from the Change Setup menu to reset the unit’s Channel 1 configuration,
Channel 2 configuration, E-mail settings, and Expert settings to the factory default settings. The server
configuration settings for IP address, gateway IP address, and netmask remain unchanged. The
configurable pins’ settings also remain unchanged. The specific settings that this option changes are
listed below:
Channel 1 Configuration
Baudrate 9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C)