34
4 Once the key number is completed, the controller begins to alternately flash green and
red to signify that it is searching for Wi-Q Gateways in range. If the sequence was
completed successfully, three green flashes indicate the controller has accepted the sign
on key.
5 If you see three red flashes, the controller has not accepted the number or you have
exceeded the time limit. Begin again at step two and continue until you receive three
green flashes.
Note
Once a controller has been signed on, all sign-on functionality is disabled unless it is deep-
reset.
Signing on Card Readers
If your segment uses card readers, you may want to register one of your cards with a
segment credential number (See “Segments and Segment Sign On Credentials” on
). This card will be used to sign on card readers to the system. You can register a
separate card and hold it specifically for this purpose, or register one that belongs to a user
such as the Administrator’s card. Once this is done, you will use the card to sign on each
card reader in the system.
Verify Signal Strength, Voltage and Packet Transfer Ratio
If you used the Wi-Q Technology Site Survey Kit, you have already verified basic controller
signal strength. Once the controllers are signed on, you can use the Alarm Monitoring
application to further measure controller performance, including controller voltage (battery
level), and the packet ratio (the number of packets received vs the number of packets sent)
of the controller. For more information about the Alarm Monitoring application, see the
Alarm Monitoring User Guide.
Replacing a Controller
If you must replace an old or defective Controller with a new one, follow these steps:
1 Ensure that the Controller is online and associated with any Wi-Q Gateway. Send a deep
reset to the Controller if needed.
2 Remove Wi-Q Controllers from assigned access levels in System Administration before
deleting them from Readers and Doors.
3 Inside the Readers and Doors Module, Click Add button and enter the controller name
followed by MAC address. Example: Controller1(0014f5123456)
4 Select OK button and confirm the changes.
5 Sign on the new controller. And the configuration should be automatically sent to it.
Содержание BEST Wi-Q ONGUARD
Страница 7: ...A Glossary Glossary 109 B Lock Installation Lock Installation 113 ...
Страница 40: ...40 2 Select Inbound Rules Figure 13 Inbound Rules Select Inbound Rules ...
Страница 44: ...44 6 Select Allow the connection Click Next to continue See Figure 17 Figure 17 Allow the Connection ...
Страница 45: ...45 7 De select the Public option Click Next Figure 18 De select Public ...
Страница 52: ...52 Figure 27 Wi Q Interface Setup Wizard Click Next ...
Страница 57: ...57 Figure 33 Custom Setup Options Click Next ...
Страница 58: ...58 10 The wizard is now ready to begin installation Click Install Figure 34 Begin Installation Click Install ...
Страница 75: ...75 To add a new Sign On Credential 1 Select Add Figure 52 Add Segment Sign On Credential 1 ...
Страница 113: ...B Lock installation ...
Страница 168: ...6161 East 75th Street Indianapolis IN 46250 USA Phone 1 800 392 5209 https dhwsupport dormakaba com hc en us 172713 S3 ...