OP000471
Inspection, Maintenance and Adjustment
4-60
Travel Motor
NOTE:
Perform this only when oil is drained from travel
motor
1.
Shut down engine
2.
Disconnect drain hose (Figure 77) and fill motor case
with hydraulic oil.
3.
Connect drain hose.
4.
Start engine and set engine speed control dial to "LOW
IDLE." Run the engine for one minute and slowly drive
excavator forwards and backwards.
General Venting
1.
After venting air from all components, shut the engine
down and check the hydraulic oil level. Fill hydraulic oil
tank to "H" mark on sight gauge.
2.
Start engine and operate all controls again, run engine
for five minutes to ensure all systems have been vent
and purged of air. Set engine speed to "LOW IDLE,"
and check hydraulic oil level again. Add oil as
necessary.
3.
Check for oil leaks and clean all fill and venting
locations.
Figure 77
FG007712
Содержание DX35Z
Страница 2: ......
Страница 6: ...Table of Contents K1025196E IV Index 8 1 ...
Страница 60: ...OP000468 Safety 1 54 ...
Страница 64: ...OP000469 Operating Controls 2 4 OPERATOR S AREA FG007488 2 6 1 4 3 10 9 7 5 12 11 13 8 15 14 Figure 2 ...
Страница 66: ...OP000469 Operating Controls 2 6 OPERATIONAL CONTROLS AND PANELS 5 6 11 10 9 8 4 3 2 1 7 FG007489 Figure 3 ...
Страница 90: ...OP000469 Operating Controls 2 30 ...
Страница 132: ...OP000470 Operation 3 42 ...
Страница 176: ...OP000471 Inspection Maintenance and Adjustment 4 44 6 Roll the new O ring 1 into the O ring groove 1 FG007697 Figure 59 ...
Страница 204: ...OP000473 Specification 7 2 OVERALL DIMENSIONS A B D E F M K L G O N H I U T S R Q P J C 5 0 7 0 FG007625 Figure 1 ...