OP000471
Inspection, Maintenance and Adjustment
4-38
12,000 HOUR / SIX YEAR
SERVICE
Hose In-service Lifetime Limit (European
Standard ISO 8331 and EN982 CEN)
European regulations state that the in-service life of any
hydraulic hose may not exceed six years.
DOOSAN
recommends the following:
•
Hoses at the customer premises cannot be stored
more than 2 years before being discarded or
installed on a machine.
•
In-service lifetime of hoses fitted on a machine
can never exceed 6 years, but replace hoses
described in “Major Parts - Periodic Replacement”
on page 4-37, every 2 years. Always replace
hoses having exceeded the allowed in-service
lifetime irrespective of the external appearance/
wear.
•
Always store hoses in a dark place at a maximum
of 65% relative humidity, between 0°C (32°F) and
35°C (95°F) but as close as possible to 15°C
(59°F) and away from copper, manganese or tube
generating Ozone.
Содержание DX35Z
Страница 2: ......
Страница 6: ...Table of Contents K1025196E IV Index 8 1 ...
Страница 60: ...OP000468 Safety 1 54 ...
Страница 64: ...OP000469 Operating Controls 2 4 OPERATOR S AREA FG007488 2 6 1 4 3 10 9 7 5 12 11 13 8 15 14 Figure 2 ...
Страница 66: ...OP000469 Operating Controls 2 6 OPERATIONAL CONTROLS AND PANELS 5 6 11 10 9 8 4 3 2 1 7 FG007489 Figure 3 ...
Страница 90: ...OP000469 Operating Controls 2 30 ...
Страница 132: ...OP000470 Operation 3 42 ...
Страница 176: ...OP000471 Inspection Maintenance and Adjustment 4 44 6 Roll the new O ring 1 into the O ring groove 1 FG007697 Figure 59 ...
Страница 204: ...OP000473 Specification 7 2 OVERALL DIMENSIONS A B D E F M K L G O N H I U T S R Q P J C 5 0 7 0 FG007625 Figure 1 ...