OP000471
Inspection, Maintenance and Adjustment
4-24
5.
Clean the outer filter (3, Figure 35) by blowing
compressed air from the inside of the filter towards the
outside. Do not use more than 205 kPa (30 psi) air
pressure.
6.
Check outer filter by shinning a light through it. If small
holes or thinner parts are found on the element after
cleaning it, replace the filter.
7.
Clean the inside of the air cleaner body and the inside
of the air cleaner cover. Do not use compressed air.
8.
Properly install the air filter and cover.
9.
After filter service be sure to install cover with arrows
pointing "UP."
Change Engine Oil and Filter
NOTE:
Change engine oil and filter after first 50 hours of
operation or rebuild, then every 250 thereafter.
1.
Position a larger container under the engine. Remove
cap (1, Figure 37) and install hose to drain the engine
oil. Remove hose and install cap (1).
NOTE:
Dispose of drained fluids according to local
regulations.
HAOC570L
Figure 35
FG000412
Figure 36
WARNING!
DO NOT change oil on a hot engine. Allow the engine
to cool down before attempting to change the engine oil
and filter to avoid burns by touching hot engine parts.
Figure 37
1
FG007679
Содержание DX35Z
Страница 2: ......
Страница 6: ...Table of Contents K1025196E IV Index 8 1 ...
Страница 60: ...OP000468 Safety 1 54 ...
Страница 64: ...OP000469 Operating Controls 2 4 OPERATOR S AREA FG007488 2 6 1 4 3 10 9 7 5 12 11 13 8 15 14 Figure 2 ...
Страница 66: ...OP000469 Operating Controls 2 6 OPERATIONAL CONTROLS AND PANELS 5 6 11 10 9 8 4 3 2 1 7 FG007489 Figure 3 ...
Страница 90: ...OP000469 Operating Controls 2 30 ...
Страница 132: ...OP000470 Operation 3 42 ...
Страница 176: ...OP000471 Inspection Maintenance and Adjustment 4 44 6 Roll the new O ring 1 into the O ring groove 1 FG007697 Figure 59 ...
Страница 204: ...OP000473 Specification 7 2 OVERALL DIMENSIONS A B D E F M K L G O N H I U T S R Q P J C 5 0 7 0 FG007625 Figure 1 ...