Installation, Operation and Maintenance Manual
DCE 2000 Series Dust Collectors
36
speCIfICatIon
table 7 – Compressed aIr reQuIrements
a
Normal operating pressure.
b
Recommended atmospheric air volume of clean, dry compressed air.
c
Recommended initial settings; these may be varied with experience.
d
Sizes suitable for runs of pipe up to 30 m (100ft) in length; for longer runs consult with Donaldson.
For connection details please refer to Publication 2325.
1 bar = 10
5
Pa
at 18 s intervals
c
dCe f2012
3.4 bar
50 psig
3.0 m³/h
1.8 cfm
60 ms
½" NB (12)
dCe f2018
3.4 bar
50 psig
3.4 m³/h
2.1 cfm
60 ms
½" NB (12)
Minimum
Working compressed
atmospheric
unit type
Pulse duration
pipe
air pressure
a
air volume – F.a.D.
b
diameter
d
at 12 s intervals
c
dCe f2024
3.4 bar
50 psig
7.4 m³/h
4.4 cfm
60 ms
½" NB (12)
dCe f2030
3.4 bar
50 psig
7.4 m³/h
4.4 cfm
60 ms
½" NB (12)
dCe f2036
3.7 bar
55 psig
9.5 m³/h
5.6 cfm
60 ms
½" NB (12)
dCe f2045
3.7 bar
55 psig
9.5 m³/h
5.6 cfm
60 ms
½" NB (12)
3 phase / 50 Hz
(IeC 60034-30)
230/3/50 D
400/3/50 Y
400/3/50 D
690/3/50 Y
0.75 – 1.5
nameplate details
kW
2.2 and above
220-240 D
380-420 Y
380-420 D
660-690 Y
range
250-280/3/60 D
440-480/3/60 Y
440-480/3/60 D
0.75 – 1.5
nameplate details
kW
2.2 and above
250-280 D
440-480 Y
440-480 D
range
3 phase / 60 Hz*
table 8 – standard fan motor supply VoltaGe detaIls
*Some motors will be fitted with a second nameplate displaying 60 Hz details
The details above may not apply to non-standard motors.
to comply with european standards the motor nameplate will display the following: