Installation, Operation and Maintenance Manual
DCE 2000 Series Dust Collectors
15
(
DR
connections)
On units fitted with an IPC (
DR
) Controller, the cleanside and dirtyside tapping
points require connecting as shown in Figure 8, using the
DR
connection kit
supplied.
overload protection
All feeder circuits should be adequately protected with suitably-rated fuses and
contactors with integral overload protection.
Integral fan
When the collector is fitted with a fan it should be wired to the fan terminal box
located on the side of the collector (see Fig. 1). These terminals will need to be
wired to a suitable control panel for the type of fan motor supplied. This control
panel should be designed to comply with local legislation for electrical installations
(refer also to 'Interlocks' and 'Overload protection').
Details of standard fan motor supply voltage are given in Table 8 (refer
to 'Specification' section).
InstallatIon
Figure 8 IPC (
DR
) Controller – cleanside and dirtyside tapping point connections
Upward loop to help
prevent dust ingress
Front elevation
(with access panel removed)
side elevation
In-line filter
Dirtyside connection
Cleanside connection