maIntenanCe
6 Remove fan section front panel or, on collectors with secondary/absolute
filter, open fan section door and remove secondary/absolute filter element.
7 From the front of the collector, inside the fan section, remove the bolts locating
the fan assembly to the fan division panel.
8 Remove the bolts locating the fan motor pedestal to the fan support channels.
9 The fan assembly can now be removed using a suitable lifting arrangement.
If changing fan assembly for a different type, e.g. K5 to K7, ensure the
associated fan mounting plate and fan support channels are used. If
required, any necessary electrical items should be resized.
Renewing fan impeller and/or motor:
Refer also to Table 3.
1 Make a note of the distance from either impeller back plate to fan case
(preferred) or inlet eye to impeller front plate, as this will assist with
replacement. If required, refer to Donaldson for exact dimensions.
2 From front of fan assembly (non motor end) remove impeller inlet eye from
fan casing by removing outer circle of bolts and pulling away the plate.
3 Undo grub screw that holds hub onto motor shaft.
Figure 12 secondary or absolute filter replacement
Tension latch
Clamping frame