Installation, Operation and Maintenance Manual
DCE 2000 Series Dust Collectors
13
3 Position the worm drive hose clip to suit, and tighten until sufficiently secured.
4 Take the other end of the pressure balance pipe, and slip the worm drive hose
clip over it.
5 Slide the pressure balance pipe over the bin balance spigot assembly.
6 Position the worm drive hose clip to suit, and tighten until sufficiently secured.
flat bar stiffening
For collectors operating at –1140 mm WG or collectors with top explosion relief,
a set of flat bar stiffeners is supplied with the collector. The flat bar stiffeners
should be fitted at the site joints when the collector is being installed (see Fig. 7).
Compressed air requirements
DCE 2000 Series dust collectors require an independent supply of clean, dry,
oil-free compressed air. Details of atmospheric pressure and quantity are given
in Table 7 (refer to 'Specification' section). A design label is also attached to
each manifold. Where an existing factory mains system is to be used it may be
necessary to install an additional moisture separator in the supply line to the unit.
If a compressor is being installed to supply the unit, then the following conditions
should be observed as far as possible:
Alternative cleaning gases should be assessed before use to ensure
explosive atmospheres are not introduced.
Type of compressor
Use a compressor of ample capacity – an overloaded compressor tends to
produce excessively contaminated, moisture-laden air.
InstallatIon
Stiffener
Side/Back
panel
Hopper
Stiffener
Gusset plate
Hopper site joint
typical site joint
Filter section to inlet
section site joint, rear
Back
panel
Inlet
Stiffener
(40 x 12 on wide units)
Figure 7 typical fixing positions of flat bar stiffeners