maIntenanCe
b
a
Diaphragm valve
Manifold
Figure 11 Valve diaphragm replacement
If it is found necessary to replace a diaphragm, use the following procedure (refer
also to Fig. 11):
Use service kit available from Donaldson.
1 Switch off fan and compressed air supply.
2 Remove cleaning system access panel (Fig. 1).
3 Remove 6 mm diameter nylon tube (A) by pulling out from valve.
4 Remove the hexagon head set screws and shakeproof washers securing
the valve bonnet (B).
5 The diaphragm and spring (if fitted) can now be replaced, first ensuring the
‘bleed’ hole pin is not blocked.
6 Ensure that diaphragm fits over ‘bleed’ hole pin and that the nylon sealing
washer is inside throat of valve.
7 Position spring (if fitted) inside bonnet recess.
8 Refit bonnet ensuring spring (if fitted) locates over diaphragm disc shoulder
and bonnet locates over ‘bleed’ hole pin.
9 Refit and tighten the hexagonal head set screws and shakeproof washers.
10 Push-fit 6 mm diameter nylon tube back into valve.
11 The collector is now ready to restart.
Six-monthly
The fan impellor has been dynamically balanced and the fan assembly vibration
level should be in line with category BV-3, ISO 14694. An assessment of vibration
should be made every six months, or after a significant emission, or after any
misuse and a record kept of measured values. Excessive vibration levels should
be investigated and corrected immediately.
Vibration monitoring is mandatory on category 2G, 3G and 2D fan
assemblies.