Installation, Operation and Maintenance Manual
DCE 2000 Series Dust Collectors
11
Remove lifting brackets from base section and apply sealing compound around
the flange making a continuous 5 mm bead along each side of the holes (see
Fig. 3). Lift the filter section into position and secure using nuts, bolts and washers
to form an airtight seal.
Remove lifting brackets from filter section and, repeating the procedure above,
fit the fan section.
When the collector is fitted with antistatic filter elements, an earthing
connection must be made between the base and filter sections, and
also the filter and fan sections, using the earthing straps provided (see
Figs. 4 and 5).
Hopper type collectors
When the collector is fitted with explosion relief panels, the explosion
relief area is suitable for the collector volume only. Additional protection
may be required when mounting onto other vessels.
Apply sealing compound around the mounting flange making a continuous
5 mm bead of sealant along each side of the holes (if required, details of mounting
flange fixing positions are provided in Publication 2325).
Lift the filter section into position and secure using nuts, bolts and washers to
form an airtight seal. Remove lifting brackets from filter section and apply sealing
compound around the flange making a continuous 5 mm bead along each side
of the holes. Lift the fan section into position and secure using nuts, bolts and
washers to form an airtight seal.
When the collector is fitted with antistatic filter elements, an earthing
connection must be made between the filter and fan sections, using
the earthing strap provided (see Fig. 5).
InstallatIon
Figure 5 earthing connection
between filter and fan sections
Earthing strap
Fan section
side panel
Filter section side panel
Figure 4 earthing connection
between base and filter sections
Earthing strap
Filter section
side panel
Base section side panel