Installation, Operation and Maintenance Manual
DCE 2000 Series Dust Collectors
12
Venting type collectors
Lift the base section into position and, using plumb lines and spirit levels, line
up both horizontally and vertically using shims under legs where required. Drill
through the base section holes and insert and tighten expandible bolts (if required,
details of foundation fixing positions are provided in Publication 2325). For
collectors with dust container, locate position for dust container support panel,
drill through fixing brackets and secure with bolts. Adjust height to provide an
effective seal between dust container and sealer gear.
Remove lifting brackets from base section and apply sealing compound around
the flange making a continuous 5 mm bead along each side of the holes (see
Fig. 3). Lift the filter section into position and secure using nuts, bolts and washers
to form an airtight seal.
When the collector is fitted with antistatic filter elements, an earthing
connection must be made between the base and filter sections, using
the earthing strap provided (see Fig. 4).
pressure balance pipe
When this option is fitted, the dust container may be lined with a polythene bag
which can be closed and sealed before lifting out of the container to assist in the
safe removal of toxic or noxious dusts. The containers supplied for this purpose
are fitted with a detachable pressure balance pipe to prevent the bag from being
drawn up into the collector.
To assemble the pressure balance pipe, the following procedure should be used
(refer also to Fig. 6):
1 Slip the worm drive hose clip over the pressure balance pipe.
2 Slide the pressure balance pipe over the pipe connection on the dust container.
InstallatIon
Figure 6 Pressure balance pipe arrangement
Rubber sealing strip
Dust container
Clean air chamber base
Worm drive hose clip
Bin balance spigot
assembly
Pressure
balance pipe
Worm drive
hose clip
Pipe connection
Содержание DCE 2000 Series
Страница 43: ......