Installation, Operation and Maintenance Manual
DCE 2000 Series Dust Collectors
30
1 Lift fan assembly into position.
2 Loosely replace bolts to locate the fan motor pedestal to the fan support
channels.
3 Bolt the fan assembly to the fan division panel.
4 Ensure the fan assembly is correctly positioned, then tighten bolts.
5 Replace fan section front panel or, on collectors with secondary/absolute
filter, replace secondary/absolute filter element and close fan section door.
6 Connect electrical cable to motor.
7 Replace internal baffles.
8 Replace left-hand panel of the acoustic diffuser.
9 Feed motor cable through left-hand panel and reconnect electrical cables
to terminal box.
10 Replace top plate and outlet grille or back panel.
11 Replace lifting brackets.
12 Switch on electric power.
13 Ensure correct fan rotation (refer to fan rotation label located on rear panel
of fan section).
table 3 – torQue Values for bolts WItH Iso metrIC tHread
* For nuts and bolts to ISO 4017.
8 mm
1 mm
20.1 mm²
10.4 Nm
15.3 Nm
17.9 Nm
7 mm
1 mm
28.9 mm²
17.2 Nm
25 Nm
30 Nm
8 mm
1.25 mm
36.6 mm²
25 Nm
37 Nm
44 Nm
10 mm
1.5 mm
58 mm²
50 Nm
73 Nm
86 Nm
12 mm
1.75 mm
84.3 mm²
86 Nm
127 Nm
148 Nm
14 mm
2 mm
115 mm²
137 Nm
201 Nm
235 Nm
16 mm
2 mm
157 mm²
214 Nm
314 Nm
368 Nm
18 mm
2.5 mm
192 mm²
306 Nm
435 Nm
509 Nm
20 mm
2.5 mm
245 mm²
432 Nm
615 Nm
719 Nm
22 mm
2.5 mm
303 mm²
592 Nm
843 Nm
987 Nm
24 mm
3 mm
353 mm²
744 Nm
1060 Nm
1240 Nm
27 mm
3 mm
459 mm²
1100 Nm
1570 Nm
1840 Nm
30 mm
3.5 mm
561 mm²
1500 Nm
2130 Nm
2500 Nm
nominal
diameter
torque value*
grade 8.8
thread
pitch
stress
area
grade 10.9
grade 12.9
maIntenanCe
Содержание DCE 2000 Series
Страница 43: ......