12. Product Standards and Specifications
12. Product Standards and Specifications
12.
Product Standards and Specifications
OSCILLOSCOPE
INPUT
BANDWIDTH/
SAMPLE RATE
20MHZ
40MHZ
60MHZ
100MHZ
200MHZ
Real Sampling
100MS/s Per Channel
200MS/s Single Channel
Real Sampling 100MS/s
per Channel, 200 MS/s
Single Channl
with 2.5 GS/s Repetive
Samling
Real Sampling 500MS/s
per Channel, 1 GS/s
Single Channl
with 5 GS/s Repetive
Samling
MODEL
820
840
860
800X
800Z
MODEL
820
840
860
800X
800Z
Input Channeis
Input Coupling
Input Impedance
Probe Attenuation
Max Input
2 Channels
DC, AC, GND
1M
Ω ±
1%, 20pF
±
3pF
x1 or x10
300V(direct input)
600V(through 10:1 Probe)
HORIZONTAL
SEC/DIV Range
Time Base Accuracy
Position Range
Delay Resolution
Delay Accuracy
Delta Time
Measurement Accuracy
Modes
XY
Horizental Pan and Zoom
50 ns/div~50 s/div 10ns/div~50 s/div
50 ns/div~50 s/div
±
0.01%
pre-Trigger : 20div max. Post-Trigger : 1000div
1/250 of screen diameter
0.04 divisions
±
3%
Main, XY
Yes
Yes
VERTICAL
Vertical Resolution
VOLTS/DIV Range
Offset(Position)
Vertical Accuracy
8-Bit
5 mV/div~100 V/div(1,2,5 Step)
±
5 div from center
±
3%
72
Hand-held Digital Oscilloscope Meter
73