After exceeding 150 seconds, the graph automatically compresses to half
screen and time base changes to 300 seconds. ( recording data compresses from
250 points to 150 points )
Note.
When automatic change from 20 minutes to 50 minutes , from 200 minutes to 300
minutes, from 20 hours to 30 hours , Screen changes 2/5 full screen or 2/3 full
screen respectively, not a 1/2 full screen
Max.Min.Average
Press key to select Max.Min,Average.
Max, Min value is the last measurement Max. Min value and Average value is
the arithmetic average value of the last 8 readings.
The real time minimum and maximum measurements are displayed Along with
the recorded data.
Logger Restart
Press key to restart recording measurement. This function is to clear the
previousely captured readings and refresh the minimm,maximum, average
values.
( When external Flash Memory device is connected, press F3 key in Menu page
2/2 to select CSV Saving time Interval . Then press F2 (CSV Saving) key to
save. )
The data logger plots the graph from left to right until the screen reaches the
right edge of the screen ,when time base changes 2 times and horizontal time
base axis value automatically compresses to half of full screen.
Time base increments changes by 10 division. (150 seconds/300 seconds/10
minutes/20 minutes/50 minutes/100 minutes/200 minutes/300 minutes/10
hrs/20 hrs/30 hrs/60 hrs/120 hrs/10 days/20 days)
10. DATA LOGGER
10. DATA LOGGER
66
Hand-held Digital Oscilloscope Meter
67