11. External Layout Summary
11 - 3. AC Power
- Input : 100V ~ 240VAC free voltage
- Output : DC12V/2A 50/60Hz (model 820, 840, 860)
DC9V/2A 50/60Hz (model 800X, 800Z)
AC power Adapter and Internal charger is supplied as standard
accessory. No other AC power adapter is used to this instrument.
DC Power
Ni-MH Battery pack can be charged by AC power adapter and internal charger
or car cigarette cable. Battery is charged while using or not in use of Instrument.
11. External Layout Summary
11 - 4. Tilt Stand
The Tilt Stand can be placed either in the locked stand position for flat surface
use or in the hinged position for hanging use.
①
For use on a flat surface, lift the Stand to approximately a 55 degree angle
and push in until the Stand locks in the holding hole.
②
To hang the meter, squeeze the legs of the Stand and remove it from the
meter. Turn the stand 180 degree and replace in the holder. The Stand will
now swing free over the top of the meter.
11 - 5. Battery Replacement
①
Disconnect the test leads from any circuit being measured.
②
Lift Tilt Stand and remove the two screws at each ends of two Battery Cover using
Philips Screw driver. (Screws are to be kept securely. Do not loose any of them)
③
Lift the two battery covers up to remove them.
④
Remove the Tilt Stand.
⑤
Replace the batteries, making sure the new batteries are located with the
correct polarity and the Metal Contacts and Springs in the Battery
Compartments are in proper contacts with the batteries.
⑥
Snap the two battery covers back into the original place and put the Tilt
Stand in the place.
⑦
Put the two screws in the place using Screw Driver.
Note.
If your meter does not work properly, check the battery to make sure that they are
still good and that they are properly inserted.(+ - polarity)
Note.
When the Battery becomes exhausted or drops below operating voltage will
dimmer or brighter warning.
Rechargeable Battery is charged while using AC Adapter. Recharging time will be
shorten if the battery is charged at Power Switch is "OFF".
When installed Ni-MH Battery is totally drain out, very rare case, Instrument may
not properly operate with AC Adapter. In this case, recharge the drained out Ni-
MH battery(being installed inside meter) with AC Adapter for about 5 minutes -
Power Switch at "OFF".
CAUTION.
Do not use non-rechargeable batteries(alkaline, carbon-zinc, etc.)
with meter's AC Power adapter. The AC Power adaptor maybe used whether
or not the rechargeable Ni-MH batteries ar installed.
WARNING.
To avoid electric shock, do not operate your meter until the
battery covers are in place and fastened securely.