www.LifeIonizers.com
17
75
DOLPHIN
IMPORTANT- - - Placing the unit in bypass
Should there be a loss of water pressure in your home (caused
by the filter), initiate a backwash by depressing the “extra
cycle” button and running a complete backwash through all 4
cycles. Should this not correct the pressure loss, place BOTH
bypass valve knobs into the” bypass” position and call your
water dealer. The two knobs are located directly behind your
automatic valve where your cold water pipes enter the unit.
The knobs will only rotate 90
o
from full service to full bypass. If
using a tool to assist turning valves use caution not to turn the
wrong way- you could damage the bypass valve!
Note:
Placing the bypass valve into the bypass position will
bypass both the filter tank and filter valve. The water entering
the home will no longer be filtered. Placing the valve handles
partially open/close will cause the water to partially bypass
unit.
•
Do not subject the unit to freezing conditions.
•
Do not exceed Max PSI 120 water pressure.
•
Do not exceed 100
o
F water Temperature.
IMPORTANT: ALL WATER TREATMENT UNITS REQUIRE
PEROIDIC SERVICING. CHANGE YOUR DOLPHIN WHOLE
HOME FILTRATION MEDIA:
• Dolphin VOC: 12-18 months
• Dolphin Heavy Metal Fluoride: 6-9 months
(Time variance is due to water quality and water usage.
For more details, contact your LIFE Ionizers™ representative.)
Caution: Your Dolphin Whole Home System will clean the
ascetics making the water “taste and look better” long after it
has ceased removing the chemicals.