Table 4–1 (Cont.) Operation/Installation Troubleshooting
Task
Problem/Symptom
What to do
Reading the
Front Panel
Display Window
No display messages
appear.
Make sure both the power switch (on the
rear panel) and the operation switch (on
the front panel) are switched on.
Check that the power cord is connected.
Check AC input.
Check the fuse.
Check the control panel cable connections.
Replace the control panel PCA.
Replace the autochanger controller PCA.
Replace the power supply.
Reading/writing
magneto-optical
disks
Can’t write to the disk.
Check the file system access permissions.
Check the write-protect tab on each disk
side to assure write-enabled status.
Check to make sure the disk was
initialized.
Check that the disk file system was
mounted correctly.
Check your application software.
Removing disks
Disk removal attempted,
but the storage slot
or drive location won’t
display the option.
Make sure the optical disk surface’s file
systems have been unmounted.
Disk removal attempted,
but a
FULL
or
MISLOAD
message displays.
Remove the disk from the mailslot and try
to remove the desired disk again.
(continued on next page)
Troubleshooting and Diagnostics 4–5
Содержание RW504-ZA
Страница 10: ......
Страница 42: ......
Страница 58: ......
Страница 106: ......
Страница 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Страница 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Страница 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Страница 148: ......
Страница 206: ......
Страница 210: ......
Страница 219: ...Voltage Configuration 2 10 Index 5 ...
Страница 220: ......