Table A–3 (Cont.) Autochanger Micro-Move Error Codes
Error
Code
(hex)
Description
71
Could not verify that the drive ejected the cartridge.
72
Could not free fingers from the drive.
73
No cartridge in drive.
74
No load complete.
75
Drive error signal.
76
Unexpected cartridge in the drive.
77
Unexpected load complete.
78
Exhausted retries attempting to get drive to accept the cartridge.
79
Could not verify that the drive accepted the cartridge.
7E
Inline recovery attempts exhausted.
Errors above are counted in the runtime log as in-line, errors below as retries.
90
Drive access was disallowed because drive busy signal was active.
91
Drive light stuck off.
94
Outside mailslot sensor failed.
95
Inside mailslot sensor failed.
96
Mailslot rotation failure; possibly caused by operator.
FA
Test drive insert retry.
FB
Timed out waiting for drive to eject when testing for the presence of a cartridge;
retry being attempted.
FC
Retry being attempted on drive insert.
FD
Retry being attempted on drive eject.
FE
Mechanism error.
A.3 Drive SCSI-2 Reference
This section contains the following information:
Request Sense Command sense key values
Request Sense Command additional sense code values
HP-Specific Error Codes
Offline Diagnostic Information A–13
Содержание RW504-ZA
Страница 10: ......
Страница 42: ......
Страница 58: ......
Страница 106: ......
Страница 145: ...Figure 5 22 Optical Disk Library Exploded View Sheet 1 of 3 Removal and Replacement 5 39 ...
Страница 146: ...Figure 5 23 Optical Disk Library Exploded View Sheet 2 of 3 5 40 Removal and Replacement ...
Страница 147: ...Figure 5 24 Optical Disk Library Exploded View Sheet 3 of 3 Removal and Replacement 5 41 ...
Страница 148: ......
Страница 206: ......
Страница 210: ......
Страница 219: ...Voltage Configuration 2 10 Index 5 ...
Страница 220: ......