Figure 5–12 Removing the Drive Plate and Optical Sensor
When reassembling:
•
Make sure the drive is positioned correctly when reattaching the drive to the
drive plate:
Position the drive mechanism in upside down in front of you so that the
front of the drive mechanism is facing toward you. Set the drive plate on
top of the drive mechanism so that the sensor is facing toward you with
the opening on the sensor facing to the right and the cables to the left.
Replace the screw in the left hole closest to you first. (Loosely tightening
this screw will cause the other holes in the drive plate to correctly align
with the holes in the drive mechanism.)
Removal and Replacement 5–21